[Tagging] Substation proposal approved - and a suggestion for a post-vote change

2013-10-12 Thread Ole Nielsen / osm
The substation refinement proposal has been approved by a large majority of voters. The new feature page can be found here http://wiki.openstreetmap.org/wiki/Tag:power%3Dsubstation Afterwards I regret a bit that I didn't reserve a dedicated value in the substation=* tag for the small street level

Re: [Tagging] Substation proposal approved - and a suggestion for a post-vote change

2013-10-12 Thread Martin Koppenhoefer
2013/10/12 Ole Nielsen / osm > I propose to change the meaning of "substation=distribution" to be used > only on substations at the last level of voltage transforming, thus the > small street-level transformer kiosks etc supplied with medium voltage > (typically 10-30 kV) and delivering low volta

Re: [Tagging] Call for more feedbacks about "emergency=aed" or "emergency=defibrillator"

2013-10-12 Thread Bryce Nesbitt
> From what I've seen in different pictures is that the label "AED" is > > never alone and you can read the word "defibrillator" translated into > > the local language for obvious reasons. I'm happy to see that in some > > countries, everybody knows what AED means... just think about the > > othe

Re: [Tagging] Call for more feedbacks about "emergency=aed" or "emergency=defibrillator"

2013-10-12 Thread Pieren
On Sat, Oct 12, 2013 at 8:37 PM, Bryce Nesbitt wrote: > There's a worldwide effort to adopt a single icon, and term, for these things. Icon, yes. Term, no. In latin countries, it's abbreviated as DAE or DEA. Check wikipedia interwiki's fyi, iyl. > Convention would be > aed=yes > Much like >

Re: [Tagging] Call for more feedbacks about "emergency=aed" or "emergency=defibrillator"

2013-10-12 Thread Philip Barnes
On Sat, 2013-10-12 at 11:37 -0700, Bryce Nesbitt wrote: > Another question is how to mark (and render) AED's that are locked. > Unless you have the code, > or a crowbar, those might as well be disused: or not present. The only locked one was photographed by me I believe. The instructions say t

Re: [Tagging] Substation proposal approved - and a suggestion for a post-vote change

2013-10-12 Thread François Lacombe
2013/10/12 Martin Koppenhoefer > > 2013/10/12 Ole Nielsen / osm > >> I propose to change the meaning of "substation=distribution" to be used >> only on substations at the last level of voltage transforming, thus the >> small street-level transformer kiosks etc supplied with medium voltage >> (ty

Re: [Tagging] Call for more feedbacks about "emergency=aed" or "emergency=defibrillator"

2013-10-12 Thread Bryce Nesbitt
On Sat, Oct 12, 2013 at 1:09 PM, Philip Barnes wrote: > On Sat, 2013-10-12 at 11:37 -0700, Bryce Nesbitt wrote: > > > Another question is how to mark (and render) AED's that are locked. > > Unless you have the code, > > or a crowbar, those might as well be disused: or not present. > > The only l