Do you call dlg_manage() for the initial INVITE?
Cheers,
Daniel
On 30/10/14 23:25, Yuriy Gorlichenko wrote:
> Does I need to use $dlg_var(cseq_diff) before UAC_AUTH()?
>
> If yes - How. Documentation say only that this var stores Difference
> between CSeq...
>
> 2014-10-31 1:58 GMT+04:00 Yuriy Go
Does I need to use $dlg_var(cseq_diff) before UAC_AUTH()?
If yes - How. Documentation say only that this var stores Difference
between CSeq...
2014-10-31 1:58 GMT+04:00 Yuriy Gorlichenko :
> Daniel. I installed new Kamailio 4.2.
>
> I set dialog module params like this:
>
> modparam("dialog", "d
Daniel. I installed new Kamailio 4.2.
I set dialog module params like this:
modparam("dialog", "dlg_flag", 4)
modparam("dialog", "track_cseq_updates", 1)
Call still unsuccessfull. CSeq still the same
IP 10.0.1.12.5068 > 21.47.2.3.5060: UDP, length
E..sH3..@.=.
_.aINVITE sip:891
Thanks for answer. Now will insttall it for tests.
2014-10-30 20:01 GMT+04:00 Daniel-Constantin Mierla :
> This feature (increasing/decreasing cseq for calls authenticated to the
> next hop by kamailio) is available with 4.2.0, by using dialog and uac
> modules.
>
> See more details at:
> -
>
This feature (increasing/decreasing cseq for calls authenticated to the
next hop by kamailio) is available with 4.2.0, by using dialog and uac
modules.
See more details at:
-
http://by-miconda.blogspot.de/2014/10/kamailio-42-tips-7-increment-cseq-for.html
Let me know if works ok for you, as I d
As I understand UAC module can not be used at production as module
foroutgoing calls from kamailio to provider with this limitations?
2014-10-30 18:24 GMT+04:00 Pavel Eremin :
> No way. Use sems or b2b.
> 30.10.2014 19:59 пользователь "Yuriy Gorlichenko"
> написал:
>
>> Does it possible increase
No way. Use sems or b2b.
30.10.2014 19:59 пользователь "Yuriy Gorlichenko"
написал:
> Does it possible increase cSeq manually (for example remove and then
> append headers?) for UAC module when send INVITE messages with Auth, or
> kamailio have pseudovar for this header?
>
>
Yes, you can. But this will break subsequent CSeq numbers in all requests
within the dialog. Also, you will need to restore proper CSeq for replies
to the INVITE for which the CSeq was altered.
-ovidiu
On Oct 30, 2014 9:59 AM, "Yuriy Gorlichenko" wrote:
> Does it possible increase cSeq manually
Does it possible increase cSeq manually (for example remove and then
append headers?) for UAC module when send INVITE messages with Auth, or
kamailio have pseudovar for this header?
___
SIP Express Router (SER) and Kamailio (OpenSER) - sr-users mailing l