Wolf wrote:
> Thanks for the update.
>
> Vendor Specific SMART Attributes are now shown ok, but there are still
> some errors:
> > Error SMART Error Log Read failed: Input/output error
> I'm not sure if it's related to smartctl or drive itself.
>
It is probably related to smartctl, see
http://so
Hi,
Thanks for the update.
Vendor Specific SMART Attributes are now shown ok, but there are still
some errors:
> Error SMART Error Log Read failed: Input/output error
I'm not sure if it's related to smartctl or drive itself.
Logs are attached.
-- Wolf
On 2010-08-20 08:34, Christian Franke
Christian Franke wrote:
> Wolf wrote:
>
>> Hi,
>>
>>
>> In attachment there is result of smartctl with -r ioctl,2
>>
>> Hope this help.
>>
>>
> [...]
> Other features (e.g. new format of Power_On_Hours) will be added soon.
>
Done in r3134.
Please test smartctl from current SVN. It s
Wolf wrote:
> Hi,
>
>
> In attachment there is result of smartctl with -r ioctl,2
>
> Hope this help.
>
Thanks.
> 177 Wear_Leveling_Count 0x 000 000 ---Old_age Offline
> - 0
> 177 Wear_Leveling_Count<== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS
> TWO
> 181
Hi,
Christian Franke wrote:
> In the OCZ forum "GrayWolf" thankfully did so
>
http://www.ocztechnologyforum.com/forum/showthread.php?76514-Vertex-2-SMART-says-drive-is-failing&p=544788&viewfull=1#post544788
> and got:
>
> --8<
> smartctl 5.39.1 2010-
Hi Frieder,
> Am 30.07.2010 18:43, schrieb Christian Franke:
>
>> Attached is a suggested database entry, please test (use -B option or
>> copy file to /etc).
>>
>>
> In the OCZ forum "GrayWolf" thankfully did so
>
> http://www.ocztechnologyforum.com/forum/showthread.php?76514-Vertex-2
Hi Christian,
Am 30.07.2010 18:43, schrieb Christian Franke:
>
> Attached is a suggested database entry, please test (use -B option or
> copy file to /etc).
>
In the OCZ forum "GrayWolf" thankfully did so
http://www.ocztechnologyforum.com/forum/showthread.php?76514-Vertex-2-SMART-says-drive-i
Frieder Ferlemann wrote:
Hi,
Am 15.07.2010 12:41, schrieb Manfred Schwarb:
play an important role, of course. So we may need to change these
settings as soon as we have some information about them.
Hi,
they have been published here yesterday:
http://www.ocztechnologyforum.com/forum/
Hi,
Am 15.07.2010 12:41, schrieb Manfred Schwarb:
> play an important role, of course. So we may need to change these
> settings as soon as we have some information about them.
Hi,
they have been published here yesterday:
http://www.ocztechnologyforum.com/forum/showthread.php?75786-SMART-Attribu
> Hi Manfred,
>
> Am 14.07.2010 23:23, schrieb Manfred Schwarb:
> > Am 13.07.2010 12:05, schrieb Frieder Ferlemann:
> >> I don't believe the OCZ-AGILITY2 is supported with the r3123 change:)
> > For me it works, why do you believe this is not correct?
>
> because the smart attributes the drive h
Hi Manfred,
Am 14.07.2010 23:23, schrieb Manfred Schwarb:
> Am 13.07.2010 12:05, schrieb Frieder Ferlemann:
>> I don't believe the OCZ-AGILITY2 is supported with the r3123 change:)
> For me it works, why do you believe this is not correct?
because the smart attributes the drive has available
1, 5
Am 13.07.2010 12:05, schrieb Frieder Ferlemann:
> Hi,
>
> I don't believe the OCZ-AGILITY2 is supported with the r3123 change:)
>
> --- trunk/smartmontools/drivedb.h 2010/06/14 16:44:37 3121
> +++ trunk/smartmontools/drivedb.h 2010/07/11 22:35:19 3123
> @@ -170,7 +170,7 @@
> " -v 213,raw64"
> },
>
Hi,
I don't believe the OCZ-AGILITY2 is supported with the r3123 change:)
--- trunk/smartmontools/drivedb.h 2010/06/14 16:44:37 3121
+++ trunk/smartmontools/drivedb.h 2010/07/11 22:35:19 3123
@@ -170,7 +170,7 @@
" -v 213,raw64"
},
{ "OCZ Agility SSD",
-"OCZ[
seems the only attributes publicly known for the
OCZ-AGILITY2 (SSD drive with sandforce controller)
are 5
http://crystalmark.info/software/CrystalDiskInfo/manual-en/HealthStatus.html
and 177 (Wear Range Delta) according to the changelog (for firmware 1.10).
(177 would be newer than the firmware
14 matches