Hello,
Am 19.06.2013 17:35, schrieb Stef:
> On 19/06/2013 16:41, Thorsten M?ller wrote:
>>
>> This seems to solve the problem. Now scanimage does tiff scans again and
>> includes the icc profile.
>>
>> Thanks
>> Thorsten
Yesterday's version of my Ubuntu ppa (ppa:rolfbensch/sane-git) has been
buil
On 19/06/2013 16:41, Thorsten M?ller wrote:
>
> This seems to solve the problem. Now scanimage does tiff scans again and
> includes the icc profile.
>
> Thanks
> Thorsten
OK,
thanks for the test. I have updated scanimage to protect itself
from these incorrect options. I have also update
Am Dienstag, 18. Juni 2013, 22:00:21 schrieb Stef:
> On 18/06/2013 21:22, m. allan noah wrote:
> >> I eventually found the root of the problem. Two option groups
> >> didn't
> >>
> >> have there .cap value defined explicitly. This was working until it
> >> broke recently, possibly relate
On 18/06/2013 21:22, m. allan noah wrote:
>> I eventually found the root of the problem. Two option groups didn't
>> have there .cap value defined explicitly. This was working until it broke
>> recently, possibly related to the use of a newer compiler. However I pushed
>> a fix in git, and now
On 14/06/2013 20:30, Stef wrote:
> On 14/06/2013 17:46, Rolf Bensch wrote:
>> Hello,
>>
>> Am 13.06.2013 20:45, schrieb Stef:
>>> On 13/06/2013 12:26, Thorsten M?ller wrote:
Hello,
I've got a problem with the 1.0.24 genesys backend. I need to use
1.0.24
since the 5 front p
>
> I eventually found the root of the problem. Two option groups didn't
> have there .cap value defined explicitly. This was working until it broke
> recently, possibly related to the use of a newer compiler. However I pushed
> a fix in git, and now this issue is fixed.
>
>
Sounds like we nee
On 14/06/2013 17:46, Rolf Bensch wrote:
> Hello,
>
> Am 13.06.2013 20:45, schrieb Stef:
>> On 13/06/2013 12:26, Thorsten M?ller wrote:
>>> Hello,
>>>
>>> I've got a problem with the 1.0.24 genesys backend. I need to use 1.0.24
>>> since the 5 front panel buttons of my CanScan LidE 210 are not fully
Hello,
Am 13.06.2013 20:45, schrieb Stef:
> On 13/06/2013 12:26, Thorsten M?ller wrote:
>> Hello,
>>
>> I've got a problem with the 1.0.24 genesys backend. I need to use 1.0.24
>> since the 5 front panel buttons of my CanScan LidE 210 are not fully
>> supported in earlier versions.
>>
>> When I tr
On 13/06/2013 12:26, Thorsten M?ller wrote:
> Hello,
>
> I've got a problem with the 1.0.24 genesys backend. I need to use 1.0.24
> since the 5 front panel buttons of my CanScan LidE 210 are not fully
> supported in earlier versions.
>
> When I try to scan in tiff format, this it what happens:
>
>
---
Message: 1
Date: Thu, 13 Jun 2013 12:26:58 +0200
From: Thorsten M?ller
To: sane-devel at lists.alioth.debian.org
Subject: [sane-devel] Sane genesys Backend 1.0.24 CanoScan LiDE 210
and tiffscan format
Message-ID: <3198229.lUCPXkXujj at dungeonmaster>
Hello,
I've got a problem with the 1.0.24 genesys backend. I need to use 1.0.24
since the 5 front panel buttons of my CanScan LidE 210 are not fully
supported in earlier versions.
When I try to scan in tiff format, this it what happens:
| tm at dungeonmaster:~ $ scanimage --format=tiff > /tmp/