Hello,
On Monday 14 February 2005 10:19, Johannes Berg wrote:
> Yes. Call Nikon, they'll point you to the application forms. You have to
> sign a NDA and they send you the docs on CDs.
well, i sent the request for the SDK some weeks ago, and now i called to
know the status of my request and they
Hubert Figuiere wrote:
>Can we have the documentation of the scanner protocol ? :-)
>
>
Yes. Call Nikon, they'll point you to the application forms. You have to
sign a NDA and they send you the docs on CDs.
johannes
> >Thanks a lot Ariel. I have no time at all these days, anyone like to
> >volunteer to have a look?
>
> Can we have the documentation of the scanner protocol ? :-)
Ah! that way it would be easy... the whole fun is doing that without
it!! ;-))
Ariel
On Wed, 2005-02-09 at 00:57 +, Major A wrote:
>Thanks a lot Ariel. I have no time at all these days, anyone like to
>volunteer to have a look?
Can we have the documentation of the scanner protocol ? :-)
Hub
--
Crazy French - http://www.figuiere.net/hub/
Hi,
> A typical block is appended, i will put the full log online tomorrow, i'll
> let you know.
i've put the full logs of the nikonscan communication with the coolscan LS50ED
in
http://cvs.fzk.de/~ariel/linux/scanner/cs2usb.log.gz
http://cvs.fzk.de/~ariel/linux/scanner/cs2usb.cleaned.log.gz
bo
> i've put the full logs of the nikonscan communication with the coolscan LS50ED
> in
> http://cvs.fzk.de/~ariel/linux/scanner/cs2usb.log.gz
> http://cvs.fzk.de/~ariel/linux/scanner/cs2usb.cleaned.log.gz
Thanks a lot Ariel. I have no time at all these days, anyone like to
volunteer to have a look
Hi Johannes and Andras,
yes, it has been a long time since my last mail... :-( i've been quite busy but
i also spent some time trying to do a usb dump of the Nikonscan communication
with the scanner. After spending some time searching for how to make it i was
amazed to see that a simple mini-scan
Hi,
> What we need is someone to spare a few hours and check the USB log of
> VueScan or Nikonscan against the Coolscan2 code. There's something the
> scanner doesn't like which is probably not even prohibited by the
> specs. Any takers? I can send you the latest version of Coolscan2 with
> which
> I saw your patch to the list also, so i will try that one instead of (or in
> addition to) the normal code. Which log can you send? the one of the
> Nikonscan?
Use the code with caution, I realized after posting that I commented
out a few parts of the code just to eliminate possible sources of
Il giorno mer, 05-01-2005 alle 12:12 +, Major A ha scritto:
> > Any suggestions for further tests/debugging info is welcome.
>
> What we need is someone to spare a few hours and check the USB log of
> VueScan or Nikonscan against the Coolscan2 code. There's something the
> scanner doesn't like
> Oh. Weird, ok. I'll keep looking. Do you have access to the technical=20
> specs of the 50/5k?
Yes, and I can't see anything obviously wrong. But then I don't have
time to go through it in detail anyway.
> Could you send me said patch? I don't have the device (yet) but would=20
> like to look o
> Any suggestions for further tests/debugging info is welcome.
What we need is someone to spare a few hours and check the USB log of
VueScan or Nikonscan against the Coolscan2 code. There's something the
scanner doesn't like which is probably not even prohibited by the
specs. Any takers? I can sen
Hi,
> Apparently it does not work, sorry. As you noticed, I had cross-posted
> to sane-devel, and Andras said he also had tried that. I'm waiting for
> him to send me more of his recent code now.
i've being playing with the trivial "add-the-missing-ids" patch today, and i
realized that there is
Major A schrieb:
>That's my problem exactly. I've tried the patch you attached, and a
>few things more, without any success so far.
>
>
Oh. Weird, ok. I'll keep looking. Do you have access to the technical
specs of the 50/5k?
>There's one major difference between the specs and the code: the
>L
> So I've been looking through the code and the specs and couldn't really
> find anything that differs between the LS50ED specs and the current
> coolscan2 code. Here's a trivial patch to enable the detection of the
> LS50 and LS5000, maybe this is all that is required to get these devices
> to
This is a multi-part message in MIME format.
--070209090002000602030408
Content-Type: text/plain; charset=ISO-8859-1; format=flowed
Content-Transfer-Encoding: 7bit
Ariel Garcia schrieb:
> great, then send me the code, i will test it asap to see how far is
> goes with that
So I've b
16 matches