Stef,
I tried a few scans with the latest code. It seems to find the start
position much better. It even works when I have Top-left x and y set to
something other than 0, which was broken for me before.
However, the colours are way off for my scanner. All the colour scans I
do are saturated to
Le Dimanche 28 Mai 2006 20:20, Fred Odendaal a ?crit?:
> Stef,
>
> You are correct about the dot. I've attached 2 files:
> find_start_lexmark1.pnm - This was with SANE_DEBUG_SANEI_USB=255
> find_start_lexmark2.pnm - This was with SANE_DEBUG_SANEI_USB unset.
>
> As you can see the picture gets bette
Skipped content of type multipart/alternative-- next part
--
A non-text attachment was scrubbed...
Name: find_start_lexmark1.pnm
Type: image/x-portable-anymap
Size: 5205 bytes
Desc: not available
Url :
http://lists.alioth.debian.org/pipermail/sane-devel/attachments/2006052
Grr,
here's the mentioned picture .
-- next part --
A non-text attachment was scrubbed...
Name: find_start.pnm
Type: image/x-portable-pixmap
Size: 5205 bytes
Desc: not available
Url :
http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20060
Le Dimanche 21 Mai 2006 03:41, Fred Odendaal a ?crit?:
> St?phane,
>
> When I tried the default maximum scan size at 150dpi I got blue streaks
> down the middle of the scan. Also, it had the wrong initial y position
> as it scanned the area off the glass and didn't scan to the maximum y
> coordinat
St?phane,
When I tried the default maximum scan size at 150dpi I got blue streaks
down the middle of the scan. Also, it had the wrong initial y position
as it scanned the area off the glass and didn't scan to the maximum y
coordinate. It also rewound to far.
When I tried smaller scans at 75 dp
St?phane
Much better. I was able to do a scan. However, the scan had blue streaks
down the middle. It also started the scan too early (you can see the
area off the glass) and the rewind went too far (you could hear the scan
head hitting the end). I can create logfiles if you want. Just let me
St?phane,
I tested it on my Lexmark X1185.
It is broken really badly. It hangs in the function
sanei_lexmark_x1100_search_home_fwd - infinite read loop in a poll after
trying to move the scan head. I did a register compare from usb dumps of
a good scan (sane-backends-1.0.17) and a bad scan (ex