Hi,
On Sat, Aug 13, 2005 at 09:36:32PM +0200, Till Kamppeter wrote:
> What was missing was the directory for the lock files. After doing
>
> mkdir -p /var/lib/lock/sane/
>
> the scanner is found.
>
> So the bug is that "make install" does not create this directory.
backend/Makefile does mkdir
Henning Meier-Geinitz wrote:
> Hi,
>
> On Sat, Aug 13, 2005 at 09:14:13PM +0200, Till Kamppeter wrote:
>
>>Oi,
>>
>>after upgrading to SANE 1.0.16 the Epson Perfection 1260 Photo is not
>>recognized by the "plustek" backend any more. See
>
>
> The important part is:
> [plustek] sanei_access_lo
Hi,
On Sat, Aug 13, 2005 at 09:14:13PM +0200, Till Kamppeter wrote:
> Oi,
>
> after upgrading to SANE 1.0.16 the Epson Perfection 1260 Photo is not
> recognized by the "plustek" backend any more. See
The important part is:
[plustek] sanei_access_lock failed: 11
Maybe you don't have the necessa
Oi,
Christian, I am forwarding this to the HPLIP developer team at HP.
Dave, Shiyun, would it be possible to let HPLIP also support the
OEM/rebadged devices like the Olivetti job_jet series? AFAIR it supports
also Apollo and this Sony MF device.
I will forward you the rest of the thread in a s
Oi,
after upgrading to SANE 1.0.16 the Epson Perfection 1260 Photo is not
recognized by the "plustek" backend any more. See
http://www.linuxprinting.org/till/tmp/sane-1.0.16-epson-1260-debug-20050813.txt
This is the output of
SANE_DEBUG_PLUSTEK=255 scanimage -L
lsusb -vvv
sane-fi
Julien BLACHE wrote:
> Christian Gruber wrote:
>
>
>>>What about SANE_DEBUG_HPAIO=255 scanimage -L ?
>>
>># scanimage -L
>>device `hpaio:/usb/Job_Jet_M400?serial=MY3B7S62T282' is a hp
>>Job_Jet_M400 multi-function peripheral
>
>
> Ah, well, they do not follow the SANE convention here.
>
> Try
Christian Gruber wrote:
>> What about SANE_DEBUG_HPAIO=255 scanimage -L ?
>
> # scanimage -L
> device `hpaio:/usb/Job_Jet_M400?serial=MY3B7S62T282' is a hp
> Job_Jet_M400 multi-function peripheral
Ah, well, they do not follow the SANE convention here.
Try to disable all the other backends; ask
Julien BLACHE wrote:
> Christian Gruber wrote:
>
>
>># scanimage -L
>>device `hpaio:/usb/Job_Jet_M400?serial=MY3B7S62T282' is a hp
>>Job_Jet_M400 multi-function peripheral
>>
>># scanimage
>>scanimage: open of device hpaio:/usb/Job_Jet_M400?serial=MY3B7S62T282
>>failed: Error during device I/O
>
Julien BLACHE wrote:
> Christian Gruber wrote:
>
>
>># scanimage -L
>>device `hpaio:/usb/Job_Jet_M400?serial=MY3B7S62T282' is a hp
>>Job_Jet_M400 multi-function peripheral
>>
>># scanimage
>>scanimage: open of device hpaio:/usb/Job_Jet_M400?serial=MY3B7S62T282
>>failed: Error during device I/O
>
Julien BLACHE wrote:
> Christian Gruber wrote:
>
>
>>is there a way of adding support for the jobjet m400 all-in-one device
>>from olivetti? It?s an oem from the hp officejet 6110.
>>the only differnce is the usb vendor- and model-id.
>
>
> Have a look at hphoj and/or hplip, the patching shoul
Christian Gruber wrote:
> # scanimage -L
> device `hpaio:/usb/Job_Jet_M400?serial=MY3B7S62T282' is a hp
> Job_Jet_M400 multi-function peripheral
>
> # scanimage
> scanimage: open of device hpaio:/usb/Job_Jet_M400?serial=MY3B7S62T282
> failed: Error during device I/O
>
> The hplip people told me i
Christian Gruber wrote:
> is there a way of adding support for the jobjet m400 all-in-one device
> from olivetti? It?s an oem from the hp officejet 6110.
> the only differnce is the usb vendor- and model-id.
Have a look at hpoj and/or hplip, the patching should be minimal.
JB.
--
Julien BLACH
Hi,
On Sat, Aug 13, 2005 at 07:05:36PM +0200, Christian Gruber wrote:
> Hi!
>
> is there a way of adding support for the jobjet m400 all-in-one device
> from olivetti? It?s an oem from the hp officejet 6110.
> the only differnce is the usb vendor- and model-id.
Have you asked the authots of the
Hi!
is there a way of adding support for the jobjet m400 all-in-one device
from olivetti? It?s an oem from the hp officejet 6110.
the only differnce is the usb vendor- and model-id.
lG Christian
--
Christian Gruber (gpg-ID: 1019E9AD)
www.mindestens.net/contacts/cg.html
Phone: +43/(0)676 507 507
Oi,
I am packaging SANE 1.0.16 for Mandriva Linux currently. Unfortunately,
I did not get the patch for the "geniusvp2" backend applied:
---
[...]
Patch #19 (sane-backends-1.0.15-geniusvp2-0.2.1.patch.bz2):
+ /usr/bi
Dear Henning,
dear listmembers,
moving from tiff to pnm solved the issues - seems like there is a bug in SuSE
9.2, I have tried tiffdump but did not understand what was going.
If anyone is interested in more "forensic" let me know ...
I mean, I solved it for me - but the problem is not gone. I eve
Simon Munton wrote:
> EPSON GT-F500 1.16
> Thu Oct 28 2004 17:57
Mine is version 1.14, dated 20040402, according to the end of the
firmware file.
Used to work fine for transparencies with 1.0.15.
iscan 1.15.0 has version 1.16, dated 20041028. Not tested.
JB.
--
Julien BLACHE
Hi everyone,
I've just included the hp4200 backend into SANE CVS. So it will be
part of the next release of sane-backends.
The backend was written by Adrian Perez Jorge and has existed for some
years as external backend now.
See http://www.sane-project.org/lists/sane-backends-cvs.html#S-HP4200
On Thursday 11 August 2005 12:00 am, Ken Ramey wrote:
> JB Wrote:
> >Maybe it'd be interesting to compare the firmwares used.
>
> That's a good idea. I would be willing to upload my firmware for
> comparison or would even be willing to compare mine with one from
> someone who is having no problems
Reinald;
I was hoping to do an actual compare of the contents of the files. If
we find that the files have different instructions in them, that would
be a start.
BTW; is your 2480 working (including transparencies) or not? What
would be most useful would be to compare the firmware from a working
I am a volunteer with an organization called WorldVistA - www.worldvista.org -
which works to promote the use of the Department of Veterans Affairs'
"VistA", the public domain electronic medical record and hospital management
system, outside of the VA. VistA runs on Windows with Cache from
Int
Reinald Kirchner wrote:
>> Maybe it'd be interesting to compare the firmwares used.
> ok, here is mine:
> esfw41.bin -> transparency does not work at all with 1.0.15 sane backend,
> using the snapscan interface.
>
> Is the difference in the firmware-versions in the filename or something
> "insi
Ken Ramey wrote:
>>Maybe it'd be interesting to compare the firmwares used.
>
> That's a good idea. I would be willing to upload my firmware for
> comparison or would even be willing to compare mine with one from
> someone who is having no problems with the color bands and post the
> results.
>
St?phane VOLTZ wrote:
> got CVS login problems again (and still that have weird extra
> 'Password:'
> prompt). I'll commit your changes, and a few other tidbits as soon as
> possible. For now I'll do it in the experimental/genesys directory, we'll
> move it from here to sane-backends/ba
Hi,
On Fri, Aug 12, 2005 at 07:54:49PM +0200, Dieter Jurzitza wrote:
> However, when I try to do a :
>
> /usr/bin/scanimage --format=tiff --mode Gray --resolution 150 > outfile.tiff
>
> and then look into the file, the image is there - but it has the size of a
> stamp rather than of a A4-page w
Hi,
On Wed, Aug 10, 2005 at 10:41:45AM +0200, Per Arnold Bl?smo wrote:
> Thats correct, but the CD that comes with the scanner has backend for
> Linux. It uses Samsungs MFP driver, but I dont think that they are
> necessary.
Ah, ok. Can you please send the ouput of sane-find-scanner?
> A least i
Hi,
On Thu, Jul 28, 2005 at 07:20:58AM +0200, St?phane VOLTZ wrote:
> here's a patch that allow sane-find-scanner to detect rts8858c usb
> chip. It
> has been tested on a Dell A920 all-in-one device. I didn't checked it in CVS
> since we are in feature freeze. It applies to check-usb-chip
> Maybe it'd be interesting to compare the firmwares used.
ok, here is mine:
esfw41.bin -> transparency does not work at all with 1.0.15 sane backend,
using the snapscan interface.
Is the difference in the firmware-versions in the filename or something
"inside" the firmware? I think my filedate
Hi,
On Sat, Aug 13, 2005 at 06:31:33AM +0200, serja wrote:
> How can I create usblogs for this model?
The same way as with other models. For some links see:
http://www.meier-geinitz.de/sane/misc/develop.html
Bye,
Henning
Dear listmembers,
to come back to the issue I found (and thanks to Henning somewhat solved). My
situation: a scanner and a zipdrive (SCSI) sitting on the same SCSI bus on
ID5 (zipdrive) and ID6 (scanner / MUSTEK 12000SP).
Problem description:
if the light of the scanner is off (after several min
How can I create usblogs for this model?
Thanks in advance!
--- Original message ---
From: Henning Meier-Geinitz
To: sane-devel@lists.alioth.debian.org
Subject: Re: [sane-devel] HP scanjet 4370
Date: 10 ?? 2005 19:09
> Hi,
>
> On Wed, Aug 10, 2005 at 07:05:04PM +0200, Bertrik Sikken w
Hi Gerhard!
Gerhard Jaeger wrote:
> the problem seems to be the UIO Error, which also sometimes exist
> on Linux, but in the end has no effect on the functionality.
> I did quite a lot of tests these days on the LiDE20 (because of
> some calibration issues), but had no problems so far.
>
> What d
32 matches
Mail list logo