Hi,
> On Wednesday 09 February 2005 19:24, Gerhard Jaeger wrote:
> > On Wednesday 09 February 2005 13:39, Vitaly Lipatov wrote:
> > > I try to get
"Alexander E. Patrakov" wrote:
>> I have the hotplug script ready, I need to create the new files from
>> the current usermap file, and after that I'll post everything here for
>> test & review.
>
> One minor note. The scheme proposed by you at the start of this thread is
> very
> generic (in f
Radek Rurarz schrieb am Dienstag, 15. Februar 2005 12:54:
Hello,
> did anybody got this scaner working under Linux?
Yes, I did.
Haven't used it for a while now. But it worked.
Stefan
> On Thu, 2005-02-17 at 12:01 +0100, Rene Rebe wrote:
> > > I do not recommend the HP7450C for use with SANE. I spent 18 months
> >
> > I have really no idea why you needed 18 months to get the scanner
> > running. With any well done distribution it should work out of the box
You're not alo
On Friday 18 February 2005 03:02, Julien BLACHE wrote:
> I have the hotplug script ready, I need to create the new files from
> the current usermap file, and after that I'll post everything here for
> test & review.
One minor note. The scheme proposed by you at the start of this thread is very
g
Hello,
On Feb 17 11:59 Kai-Uwe Behrmann wrote (shortened):
> The goal is identification of devices to assign colour profiles precisely.
> I like to take an normal userspace application and do an query to
> an library (sane) which will provide the mentioned information about the
> image output. T
--0-795902951-1108711633=:92504
Content-Type: text/plain; charset=us-ascii
Content-Id:
Content-Disposition: inline
I have a Scanmaker E3+ that works fine on WindowsXP.
On linux, I get as far as running:
scanimage -v > test.pnm
and get:
scanimage:
scanning image of size 611x971 pixels at 24 bi
Some problems? Send again my reply...
On Wednesday 09 February 2005 19:24, Gerhard Jaeger wrote:
> On Wednesday 09 February 2005 13:39, Vitaly Lipatov wrote:
> > I try to get work Benq 5000 scanner, but it does not work:
...
> Guess you should unload the scanner module...
> Are you using 2.4 kerne
My first guess at the protocol:
* The scanner has a limited set of register settings
* Registers are written using USB 'vendor' control transfers:
* the 'value' field indicates some scanner control register index
* the 'index' field is yet unknown, related to value field
* 'requesttyperes