On Friday 06 December 2002 23:54, Henning Meier-Geinitz wrote:
> Hi,
>
> Now the new function for a message callback. I'm citing the SANE2 TODO:
>
> http://www.meier-geinitz.de/sane/sane2/sane2-api-todo
>
> | !- let backend display a frontend-info or -selection (ok/cancel)
> |dialog-box (e.g. "
On Friday 06 December 2002 20:24, Henning Meier-Geinitz wrote:
> Proposal:
>
> "... However, as options are set, other options may become active or
> inactive or their constraint may change. Thus, after setting
> an option, it may be necessary to re-read the descriptors."
>
> | Image data is coll
On Thu, 5 Dec 2002 10:15:18 +0100, Henning Meier-Geinitz wrote:
Hi,
>> >However, the code in sanei_scsi.c looks like sanei_scsi_find_devices()
>> >was also implemented for FreeBSD, OS/2, and Irix. Is this correct?
>> >Does autodetection work on these platforms?
...
>> Is there a list which backe
On Monday 09 December 2002 17:51, Matto Marjanovic wrote:
> So, how about this: remove the "frames" concept altogether. The whole
> notion of calling start_scan() repeatedly to scan the same document wa=
s
> always rather gruesome anyway.
>
> Instead, we give the choice of a PACKED (i.e. byte-
oliver.ra...@rauch-domain.de said:
> But we have to keep in mind that sane is not only made for scanners.
> There may be e.g. a telescope that produces a visible image (may be
> RGB, may be CMYK) and also additional infrared or ultra-violett data.
> We still need a way to transmit such data!
The
> But wouldn't saned then be linked against libsane-net also?
> Your solution works when the connection goes to a different host, but
> here saned on the same host is connected.
Yes, you are right.
Oliver
[CC sane-devel]
On Mon, Dec 09, 2002 at 09:16:37PM +0100, Oliver Rauch wrote:
> I think the following should work with shared libs:
>
> change the files&links /usr/local/lib/libsane*
> that are currently set to /usr/local/lib/sane/libsane-dll.so
> and set them to /usr/local/lib/libsane-net.so
Bu
I think the following should work with shared libs:
change the files&links /usr/local/lib/libsane*
that are currently set to /usr/local/lib/sane/libsane-dll.so
and set them to /usr/local/lib/libsane-net.so
Oliver
On Sunday 08 December 2002 00:48, Henning Meier-Geinitz wrote:
> Hi,
>
> On Sun, De
Hi,
On Mon, Dec 09, 2002 at 05:36:20PM +0800, Fan Dan wrote:
> I have tried and get the correctly Mustek2400usb parameters. Now I can
> scan Gray and Color Image .
Fine. The latest version of the gt68xx backend should at least detect
your scanner. I'll also add your changed from below, they wi
Hi,
On Sun, Dec 08, 2002 at 05:51:17PM +0100, abel deuring wrote:
> >I hope It won't take too long to finish the core points of SANE2.
>
> Sounds promising.
Proposals/corrections/comments welcome :-)
> >SCSI reference manual for a scanner? Haha. Never seen such a beast.
> >Either it's labeled "
>From: Oliver Rauch
>Date: Mon, 9 Dec 2002 23:36:22 +0100
>
>On Friday 06 December 2002 20:24, Henning Meier-Geinitz wrote:
>> Proposal:
...
>but this would make the sane_cancel unnecessaryly complex
>because you have to call
>
> sane_cancel
> while (sane_read != SANE_STATUS_E
On Fri, 6 Dec 2002 20:43:52 +0100
Henning Meier-Geinitz wrote:
> - define string lists similar to options themselves: each entry has a name
> (English) and a title (localized). For setting the value of the
> option, always the name of the string list is used.
> something like:
>
> SANE
Hi,
On Mon, Dec 09, 2002 at 06:37:18PM +0100, John Doe wrote:
> is it right, I have von 100 percent security that in every situation
> the -d command in scanimage runs!?
I don't know what you mean by "every situation".
The -d command is an option of scanimage, so it's always present. If
you use
OK,
is it right, I have von 100 percent security that in every situation
the -d command in scanimage runs!?
My program is for blind person like an windows reading system only on
the better OS!! hehehe!
My biggest problem are the scanner and the speech!! I develop this
system on PPC!! and their a
>On Monday 09 December 2002 17:51, Matto Marjanovic wrote:
>
>> So, how about this: remove the "frames" concept altogether. The whole
>> notion of calling start_scan() repeatedly to scan the same document was
>> always rather gruesome anyway.
>
>Hello Matto,
>this is very similar to the
Hi,
On Mon, Dec 09, 2002 at 05:42:38PM +0100, John Doe wrote:
> I have in the last week posted,
I know. Why do you open a new thread for every single message?
> is it possible to give scanimage the device, vendor and produktID
> without edit a backend?
Why do you want to edit the backend? Do yo
Hi,
I have in the last week posted, is it possible to give scanimage the
device, vendor and produktID without edit a backend?
I write a prog which using the sane api!!
Thanks
Hello, Henning:
I have tried and get the correctly Mustek2400usb parameters. Now I can
scan Gray and Color Image . But When I scanner 300dpi or more . When
Scanning , sometime read data will stop, but motor is not stop. An other is
when I set bytes per line of scanner image is larger than 800
>From: Diego Zuccato
>Date: Mon, 09 Dec 2002 00:13:01 +
>
>Henning Meier-Geinitz wrote:
>
>> And this would be returned by any SANE API function that currently
>> returns SANE_Status? Nice, because it links the error number and the
>> message. No need for an extra call to a function.
I'm probably making this more difficult than it really is, but I just
can't seem to get the scanner working. I just purchased a Scanport 3000
which is suppose to be a Microtek scanner, but usbview shows it as a
Visioneer:
USB Scanner
Manufacturer: Visioneer
Serial Number:
>On Thu, Dec 05, 2002 at 06:09:57PM +0100, Henning Meier-Geinitz wrote:
>> http://www.meier-geinitz.de/sane/sane2/
>
>| 4.3.13 sane_get_select_fd
>http://www.meier-geinitz.de/sane/sane2/0.07/doc012.html#s4.3.13
>
>This function has caused a lot of trouble and misunderstandings. Or to
>be mo
I need to purchase a scanner that is capable of scanning multiple pages
at once. A scanner with an ADF. Anyone have a good recomendation for me?
Any help is appreciated,
Matt Lung
>From: Henning Meier-Geinitz
>Date: Thu, 5 Dec 2002 22:34:09 +0100
...
>On Thu, Dec 05, 2002 at 06:09:57PM +0100, Henning Meier-Geinitz wrote:
>> http://www.meier-geinitz.de/sane/sane2/
>
>Now versioning and naming. Not all of this is strictly SANE standard
>stuff, but let's start with it:
Wow, am I late getting into this long thread... (better late than never).
>On Thu, Dec 05, 2002 at 06:09:57PM +0100, Henning Meier-Geinitz wrote:
...
>I guess the image format is the most controversal point so I'll start
>with that one. Please keep calm everyone, I don't like to create a
Good day.
Awhile back with the help of people on this list I got Sane and my
scanner playing nicely together!
Then I stoped needing to scan stuff for a bit and now when I go to scan
with Xsane it starts up just fine, looks like it's all going to work but
when you click on "preview" it says "Faile
Henning Meier-Geinitz wrote:
> And this would be returned by any SANE API function that currently
> returns SANE_Status? Nice, because it links the error number and the
> message. No need for an extra call to a function.
Yep. That's why I like this method. :-)
> However: How long is errmsg valid?
Hi,
On Sun, Dec 08, 2002 at 11:40:42PM +0100, Beat Birkhofer wrote:
> >I guess you'll have to replace the libtool used by SANE to see any
> >effect. It's generated from ltconfig and acinclude.m4.
>
> Thanks-a-lot, make works now.
Good. So I'll try to include libtool 1.4.3 into SANE CVS.
> [sane
27 matches
Mail list logo