Hi Greg,
In all the three cases, the return mode field in the Echo request packet was
set to 2 (Reply via an IPv4/IPv6 UDP packet).
--
Balaji Rajagopalan
From: Greg Mirsky
Date: Wednesday, 16 August 2017 at 8:27 PM
To: Balaji Rajagopalan
Cc: Jeffrey Haas , Kireeti Kompella ,
Thomas Nadeau ,
That sounds better. How about the following text?
The egress LSR MUST follow the procedures described in [RFC4379] in processing
the LSP Ping request. The LSP Ping reply generated by the egress MAY carry the
local discriminator assigned by it for the BFD session.
--
Balaji Rajagopalan
From: Ma
Hi Balaji,
I've been thinking about the value of including BFD Discriminator TLV in
echo reply sent by egress. What we'd expect ingress to do upon receiving
the reply? Match to bfd.remoteDiscr? I think that then echo reply must
include the value from the original BFD Discriminator TLV so that ingre