Dear all,
well I do think it works ok. but i don't know why the held parameters are
still there when i go back there again after doing the POWERPREF, GENLE.
However, I create an new EXP file and input all things back, it resumes ok.
thank you very much for your kind attention.
stephen
Brian is right there are no F (holding atomic parameters in EXPGUI). I messed F up
with V.
However I found no problem to remove them using D. Simply type "D #" where # is number
of holding parameter.
To check list of holding parameters (better before and after D) type "L".
Peter Zavalij
-O
Dear Brian
Is there a latest version of EXPGUI ?
Thanks
Selva
On Thu, 22 Apr 2004, Brian H. Toby wrote:
>
> Nope -- EXPGUI does not handle the Fix option (yet).
>
> Brian
>
> Peter Zavalij wrote:
>
> >The easiest way is to use EXPGUI graphic user interface by Brian Toby.
> >Peter Zavalij
>
Nope -- EXPGUI does not handle the Fix option (yet).
Brian
Peter Zavalij wrote:
The easiest way is to use EXPGUI graphic user interface by Brian Toby.
Peter Zavalij
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
Sent: Thursday, April 22, 2004 5:05 AM
To: [EMAIL PROT
The easiest way is to use EXPGUI graphic user interface by Brian Toby.
Peter Zavalij
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
Sent: Thursday, April 22, 2004 5:05 AM
To: [EMAIL PROTECTED]
Dear all Rietvalders,
Can anyone know how to delete the holding paramet
Dear all Rietvalders,
Can anyone know how to delete the holding parameter (F option under the atomic
parameter menu in GSAS)? since the program does not allow me to remove them
even after pressing "D" for those variables? They are still there anyway.
many thanks
stephen
Dear all Rietvalders,
Can anyone know how to delete the holding parameter (F option under the atomic
parameter menu in GSAS)? since the program does not allow me to remove them
even after pressing "D" for those variables? They are still there anyway.
many thanks