Friends and colleagues:
I recently performed a service call at a grid-tied installation we did in
2003. The homeowner noticed the daily consumption had declined to about
1/3 of typical sometime in the last year. Sure enough 2 of the three
strings (30 mods in total) of Siemens SP150s showed low
Are there burn marks on the backing?
I have had several entire array replacements in the past back in the 150-175
watt/module days. But not in a while.
Dana Orzel Great Solar Works, Inc.
C - 208.721.7003 d...@solarwork.com
Idaho Cont
Hi all,
I have a customer that has a plug with no wires on their XW AGS.
I’ve never seen that.
2 questions
1. What pins/tool do I need to install wires into it?
Or
2. Where can I buy just the plug and wire harness?
Thanks
Jay
Peltz power.
___
Wrenches, William
Yes, not as unusual as you might think, BP's did it, Suntec had numerous
issues, even Sharp
On Fri, Jun 26, 2020, 3:27 PM William Miller
wrote:
> Friends and colleagues:
>
>
>
> I recently performed a service call at a grid-tied installation we did in
> 2003. The homeowner not
Jay
I think I have one you can have. I’ll confirm in the AM.
Thank you,
Maverick
> On Jun 26, 2020, at 8:33 PM, Jay wrote:
>
> Hi all,
>
> I have a customer that has a plug with no wires on their XW AGS.
> I’ve never seen that.
>
> 2 questions
>
> 1. What pins/tool do I need to instal
5 matches
Mail list logo