Hi Michael
Do you know if Discover is coming out with larger Helios batteries? 30 amp hrs
is pretty small.
And thanks everyone for the answers.
As to the blue planet, I don’t think they need heaters. I was working on a
system with one and the battery housing was darn warm, much warmer tha
Greetings Jay,
I’ve been using Blue Ions exclusively for the last 5 years almost. Most of my
sites sit around 1800-3000’ and only had two shutdowns due to cold temps. Since
it takes such significant periods of time for that much mass to get to get
below the temps of concern it really just hasn’
1st line of defense: Agricultural seed tray heat mats w/ integral T-stat
2nd LOD: Empire wall heater (no electronics) w/ industrial temperature
controlled relay (TCR) (similar to a thermostat) set to 38 degrees
3rd LOD: Battery side of charge controller circuits have TCR controlled
contactors to b
Jay,
With the SimpliPhi's we've been installing we require a
shed on slab, walls R-21, roof, R-38 and then the smallest propane wall
heater (they use zero power to operate) we can find and set it at 55
degrees. No need for the insulated box or fretting about toasting $20K+
in bat
HI All,
As I get more calls for offgrid designs with lithium batteries I”m wondering
what you all are doing to keep the batteries warm when it gets cold. For some
of you 0 F will seem mild, others super cold.
Doing a battery box and heating that or heating the whole inverter/battery shed?
I
5 matches