Re: [RE-wrenches] Separated frames on BP modules

2009-06-25 Thread Andrew Truitt
By way of update: A meeting was recently held at the site in question and the solution was agreed upon, if not the cause. Representatives were there from BP, Unirac, the ESCO and Standard Solar. It was determined that a) the RapidRac racking was not at fault and b) the installation was performed

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Joel Davidson
work. - Original Message - From: William Miller To: RE-wrenches Sent: Monday, June 15, 2009 5:36 PM Subject: Re: [RE-wrenches] Separated frames on BP modules Joel: I am waiting for module manufacturers to incorporate a slim gutter along the short edge of the module. In

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread toddcory
Its ok Nick... I feel the same way. My problems go back to when they bought out Solarex and never issued a recall for all those defective MSX 60's out there. Todd On Monday, June 15, 2009 10:10am, "Nick Lucchese" said: Oops, this was supposed just go to Andrew. Nick On Jun 15, 2009, at 9

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread William Miller
Joel: I am waiting for module manufacturers to incorporate a slim gutter along the short edge of the module. In the gutter can be folded the PV cable with quick connects. This tray would have KOs in the ends and sides, allowing snap bushed connectivity to adjacent modules and conduit to con

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Larry Crutcher, Starlight Solar
.com Ph 323-258-8883, Mobile 323-839-6108, Fax 323-258-8885 From: re-wrenches-boun...@lists.re-wrenches.org [mailto:re-wrenches-boun...@lists.re-wrenches.org ] On Behalf Of Larry Crutcher, Starlight Solar Sent: Monday, June 15, 2009 3:05 PM To: RE-wrenches Subject: Re: [RE-wrenches] Separated frame

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Peter Parrish
re-wrenches.org [mailto:re-wrenches-boun...@lists.re-wrenches.org] On Behalf Of Nick Lucchese Sent: Monday, June 15, 2009 10:11 AM To: RE-wrenches Subject: Re: [RE-wrenches] Separated frames on BP modules Oops, this was supposed just go to Andrew. Nick On Jun 15, 2009, at 9:56 AM, Nick

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Joel Davidson
al Message - From: Peter Parrish To: 'RE-wrenches' Cc: Will Logan Sent: Monday, June 15, 2009 1:57 PM Subject: Re: [RE-wrenches] Separated frames on BP modules Well Nick, the cat's out the bag on this one. And I would encourage you and Andrew to give this issue wide

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Larry Crutcher, Starlight Solar
-wrenches.org ] On Behalf Of Nick Lucchese Sent: Monday, June 15, 2009 10:11 AM To: RE-wrenches Subject: Re: [RE-wrenches] Separated frames on BP modules Oops, this was supposed just go to Andrew. Nick On Jun 15, 2009, at 9:56 AM, Nick Lucchese wrote: Sorry to hear about the BP problems Andrew. For

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Peter Parrish
nday, June 15, 2009 10:11 AM To: RE-wrenches Subject: Re: [RE-wrenches] Separated frames on BP modules Oops, this was supposed just go to Andrew. Nick On Jun 15, 2009, at 9:56 AM, Nick Lucchese wrote: Sorry to hear about the BP problems Andrew. For what it's worth you can te

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Nick Lucchese
Oops, this was supposed just go to Andrew. Nick On Jun 15, 2009, at 9:56 AM, Nick Lucchese wrote: Sorry to hear about the BP problems Andrew. For what it's worth you can tell BP that your story just solidified another wrench's reason to never sell any of their modules ever again. Hope yo

Re: [RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Nick Lucchese
Sorry to hear about the BP problems Andrew. For what it's worth you can tell BP that your story just solidified another wrench's reason to never sell any of their modules ever again. Hope you get the customer service you deserve, Nick A Lucchese NABCEP Certified PV Installer Planet Home Ge

[RE-wrenches] Separated frames on BP modules

2009-06-15 Thread Andrew Truitt
Greetings wrenches! We recently did a small commercial system (17 kW) using BP-SX 3175 modules and the Unirac RapidRac ballasted mounting system. The flat roof is ballasted with 2" of gravel that we smoothed as much as possible but undulations are visible in the array, though the changes are neve