Re: [RE-wrenches] Golf balls and PV (was Need NT185U1 Sharp module)

2010-02-25 Thread Rob Harlan
Joel, The angle of incidence certainly has a bearing on the ability to handle impact. We installed a 9kW pole mounted system in the vicinity of a golf course. We thought the distance from the course and the trees to the north of the array would protect us. Occasional balls actually did come ove

[RE-wrenches] Golf balls and PV (was Need NT185U1 Sharp module)

2010-02-25 Thread Joel Davidson
Wrenches, UL1703 requires solar modules withstand a 5 ft-lb (6.78 J) impact from a 2-in (51-mm) steel ball weighing 1.18 lb (535 g) falling through a distance of 51 in (1.295 m). Many years ago someone (perhaps at Arco Solar in the early 1980s?) said that this force was equal to a golf ball or