Re: [RE-wrenches] AGM battery charging, more details

2011-04-26 Thread Rick Cullen - Blue Sky Energy, Inc.
Wrenches, There has been some discussion in the past few days regarding AGM batteries and charge control switching to Float based on net battery charge current matched to battery size and that our IPN-ProRemote product can provide this. Let me briefly describe what this is and how it works.

Re: [RE-wrenches] Solar Boost Controller in Senegal

2009-06-30 Thread Rick Cullen - Blue Sky Energy, Inc.
Hello Everyone, The SB50's maximum input voltage spec it 57VDC. This should be considered an absolute maximum above which the controller will be damaged in a manner not covered by warranty. Our recommendation is to not apply a total Voc at STC of more than 57V/1.25= 45.6V. There are transient