Depends on the seam profile. Same device may be used in many cases. We have
Also drilled and used the standard direct burial lugs on the underside of the
pans, at the wave when they hang over enough to get working space. Then a
horizontal run of copper wire to connect.
Don't be lulled into think
thanks glenn. and what about commercial? anyone have code references
regarding grounding when doing solar on metal roofs? i thought a few years
back there was a conversation on this but i can't seem to find it.
Adam Katzman
Autonomous Energies
PO Box 1245
Kingston, NY 12402
www.autonomousenergies.
I always recommend grounding the metal roof also, even without panels on them.
most of the sealing methods we use can insulate the rack from the roof
S5 type clamps being an exception
Just a couple thoughts from an overheated brain !
Bob Ellison
> On Jun 17, 2018, at 1:46 PM, "glenn.b...@glbcc.
We use the Ilsco SGB-4 ground lug on every pan under the array for residential
systems.
-Glenn
Sent from my Verizon LG Smartphone
-- Original message--From: AE SolarDate: Sun, Jun 17, 2018 12:29 PMTo:
RE-wrenches;Cc: Subject:[RE-wrenches] grounding on metal roofs
wrenchers,what methods ar
wrenchers,
what methods are you all using for grounding on metal roofs? thanks
adam
Adam Katzman
Autonomous Energies
PO Box 1245
Kingston, NY 12402
www.autonomousenergies.com