[RE-wrenches] Midnite Classic and SMA's Sunny Portal

2016-08-02 Thread Lou Russo
Wrenches, Do any of you have any experience with the Classic 150's data integration on the Sunny Portal using the SMA WebBox, a Sunny Island, and Midnite's MNSICOMM com box? If so, is it usable/readable to the end-user in the Sunny Portal? Midnite's manual says it is, but I wanted real world conf

[RE-wrenches] CA wrenches

2016-08-02 Thread don
Bill- When there is rebate money involved the utilities like to require a Revenue Grade meter. The list of eligible meters is on the Go Solar site http://www.gosolarcalifornia.ca.gov/equipment/system_perf.phpSMA's Sunny Beam and WebBox monitors are on the list. Give the customer a web based monitor

Re: [RE-wrenches] Pump ideas

2016-08-02 Thread Maverick Brown
Jay Will a Grundfos Mark III MQ3-45 work? With an added foot valve/screen. It comes in 120 or 240 volt and 3/4 or 1hp. Has a built in pressure tank, but I suggest adding an external P/T. Thank you, Maverick Maverick Brown Maverick Solar Enterprises, Inc. SunFlow Systems Office: 512-91

Re: [RE-wrenches] Hydrometer tube lost in a battery cell..

2016-08-02 Thread Bill Loesch
Battery utilizing solar electric and glycol utilizing solar thermal wrenches: If you use a Misco brand, model 7084VP your eye is ~7.5 inches away from something less than a drop of fluid (actually a smear of liquid) under a lighted cover. Can you use safety glasses with the Extech model? Wil

Re: [RE-wrenches] CA wrenches

2016-08-02 Thread Solar Energy Solutions
The Energy Trust of Oregon, the local administrator of the investor owned utilities incentive program, mandated an additional production meter be installed between the inverter in the circuit box for the first 11 years of the program. Finally, they changed that technical requirement so additiona

[RE-wrenches] Pump ideas

2016-08-02 Thread Jay
> Hi all I've got a pump choice question 140psi lift 3-4gpm max 12' suction out of shallow well 2' water depth in well 2' diameter well Slight sediment, clay mostly. 120/240vac power Submersible won't work, too shallow Slow pump I'm concerned about filter changes Surface pump makes most sense

Re: [RE-wrenches] Hydrometer tube lost in a battery cell..

2016-08-02 Thread William Miller
Wally: Nice to see your name. I would add this: I hate to have acid too close to my eyes. William [image: Gradient Cap_mini] Lic 773985 millersolar.com 805-438-5600 *From:* RE-wrenches [mailto:re-wrenches-boun...@lists.re-wrenches.org] *On Behalf Of *Wal

Re: [RE-wrenches] Hydrometer tube lost in a battery cell..

2016-08-02 Thread Wallace Stahle
On Aug 1, 2016, at 5:50 PM, Steve Higgins wrote: > Hey Jeremy, > > A plastic/rubber tube won't be an issue... > > Best thing to do is get them a refractometer that way the only thing you're > putting into the battery is a pipette to remove just a drop or two of > electrolyte... > > The Exte

[RE-wrenches] Sharp Triangles

2016-08-02 Thread Patrick Shortell
Good Morning Wrenches, I know im reaching here but if anyone knows where I can find some Sharp triangles, Please contact me off list. Thanks Pat -- Patrick A. Shortell *Licensed Master Electrician* *Certified Solar Installer* 71 Oregon Street Long Beach N.Y. 11561 cell: 516-477-0221 _