[RE-wrenches] flat concrete tile product of choice

2015-06-18 Thread August Goers
Hi Wrenches, We have an upcoming install on a flat concrete roof. See attached pic. We’ve used the Unirac tile hook, Pro Solar TileTrac, and QuickMount QBase products all with mixed results. I would like to find something better. Does anyone have a concrete tile product that they like? Best,

Re: [RE-wrenches] Repetitive and unknown arc-fault codes with this combination...Sunpreme bi-facial and Fronius IG

2015-06-18 Thread Jerry Shafer
We had an installation with 3, 7 let SMA's we did the same checks you did. We found a AC contactor that was causing the problem, SMA agrees that this can happen. Just a thought Jerry On Jun 18, 2015 4:31 AM, "Glenn Burt" wrote: > Have you performed insulation resistance tests on the DC conductors

Re: [RE-wrenches] Repetitive and unknown arc-fault codes with this combination...Sunpreme bi-facial and Fronius IG

2015-06-18 Thread Glenn Burt
Have you performed insulation resistance tests on the DC conductors (megger)? Sincerely, Glenn Burt Sent from my 'smart' phone so please excuse grammar and typos. -Original Message- From: "Howard Scot Arey" Sent: ‎6/‎18/‎2015 8:30 To: "re-wrenches@lists.re-wrenches.org" Subject: [RE-w

Re: [RE-wrenches] Repetitive and unknown arc-fault codes with this combination...Sunpreme bi-facial and Fronius IG

2015-06-18 Thread August Goers
Howard, We haven’t installed Fronius inverters for a while, but I have some similar experience with SMA and ABB arc-fault inverters. In only one case did we have an issue where we actually had a workmanship issue – we found an MC4 connector where the terminal wasn’t fully seated in the housing.

Re: [RE-wrenches] Repetitive and unknown arc-fault codes with this combination...Sunpreme bi-facial and Fronius IG

2015-06-18 Thread Matt Partymiller
How quickly, after reset, do you see a new arc-fault error? Same day? Month later? Have you tested string volts/amps? On Thu, June 18, 2015 8:30 am, Howard \"Scot\" Arey wrote: > I need some help please! I'm quickly losing credibility with two of my > customers. > > > > We have two installatio

[RE-wrenches] Repetitive and unknown arc-fault codes with this combination...Sunpreme bi-facial and Fronius IG

2015-06-18 Thread Howard "Scot" Arey
I need some help please! I'm quickly losing credibility with two of my customers. We have two installations with Sunpreme GxB 350 bi-facial modules and Fronius IG inverters. They keep throwing Error code 240 - arc fault on the Fronius IG. We've been up and down these installation three