Bob,
There are a lot of settings that could influence your numbers.
I guessed at Yakima, WA for the PV Watts location and using 77%, I got:
239kwh for December,
254kwh for January
361kwh for February &
531 for March.
I would predict you should have at least generated most of this amount per
m
Dear Wrenches:
What am I not seeing with this situation?
Only 133 DCkWH (120 ACkWH) during mid-December through April 6 (at least
that is what the mate and the MX80 CC say). PVWATTS predicted ~600 ACkWH.
Here are the major components of the system:
24 - Silicon Energy 190W solar modul
2 matches