Re: (RADIATOR) Multiple realms in handler

2001-09-17 Thread sthaug
> > For example we'd like to block calls from 0265773xxx and 0265774xxx to > > 0265473002. What is the most effective way of implementing this? > > A specific handler, or combination with database. > > The best way to do this probably depends on what else you have configured, > however here is a

(RADIATOR) Minor correction to 2.17.1 dictionary

2001-01-01 Thread sthaug
The following attribute from the 2.17.1 dictionary: ATTRIBUTE Acct-Link-Count 51 string should be integer instead of string, as far as I can see. Integer is consistent with the Nortel CVX1800 documentation, and also with what CVX1800 (and Ascend MAX 4000) actually sends. The s

(RADIATOR) How to log Acct-Terminate-Cause and Ascend-Disconnect-Cause to the same table column?

2001-01-01 Thread sthaug
We have a number of boxes (Ascend MAX 4000, Nortel CVX 1800) that show session termination cause using the Ascend-Disconnect-Cause attribute - and we have some (Cisco 7140 used as LNS) that use Acct-Terminate-Cause. We would like to log both of these in the same SQL table column, if possible - for

Re: (RADIATOR) Nortel CVX dictionary

2001-02-03 Thread sthaug
> The attributes 135, 136 and 137 desn't work with CVX NAS. We must use > three vendor attributes by Aptis (the manufacturers of CVX, I suppose) who has > the SMI NMPE Code 1584 (this was hard to be found :-). The vendor attributes > are 54 and 55. I'd like to hear from others using CVX