Machine?
Thanks for your time.
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
(941) 332.4900
http://www.neosmart.com
===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.
DBC SQL Server Driver][SQL
Server]Vi
olation of PRIMARY KEY constraint 'pk_Calls'. Cannot insert duplicate key in
obj
ect 'Calls'. (SQL-23000)
[Microsoft][ODBC SQL Server Driver][SQL Server]The statement has been
terminated
. (SQL-01000)(DBD: st_execute/SQLExecute err=-1)
-C
-Terminate-Cause,integer
AcctColumnDef NASIdentifier,NAS-Identifier
AcctColumnDef NASIdentifier,NAS-IP-Address
AcctColumnDef NASPort,NAS-Port,integer
TimeBanking
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
(941) 332.4900
http://www.neosmart.com
===
Archive at http://www.
Without specifing a port in the config file what is the default port in
which the nas would point to for authenication and for accounting? i think
it is 1645 and 1646. A quick reply would be great thanks
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
(941) 332.4900
http
smoothly :)
thanks in advance
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
(941) 332.4900
http://www.neosmart.com
===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.
tColumnDef NASPort,NAS-Port,integer
TimeBanking
# AuthSelect ,sa.maxsessions
# AuthColumnDef 0,Simultaneous-Use,check
--/Config--
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
(941) 332.4900
http://www.neosmart.com
===
Archive at http://www.thes
When i do this, and i goto user attributes, and click new, i add the user
and none of the pull downs have anything in them... is there anywhere i can
get more info on this aspect of platypus?
thanks
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
(941) 332.4900
http://www.neosmart.com
eger
AcctColumnDef NASIdentifier,NAS-Identifier
AcctColumnDef NASIdentifier,NAS-IP-Address
AcctColumnDef NASPort,NAS-Port,integer
TimeBanking
# AuthSelect ,sa.maxsessions
# AuthColumnDef 0,Simultaneous-Use,check
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
What im inquiring about is to see if there is a way to make sure Radiator is
running and if not to spawn the process again for NT
Thanks in advance...
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
(941) 332.4900
http://www.neosmart.com
===
Archive at http://www.thesite.com.au
L Server]Cannot insert the
value
NULL into column 'UserName', table 'platypus.dbo.Calls'; column does not
allow n
ulls. INSERT fails. (SQL-23000)
[Microsoft][ODBC SQL Server Driver][SQL Server]The statement has been
terminated
. (SQL-01000)(DBD: st_execute/SQLExecute err=-1)
Mon Nov 22 14:06:44 1999: ERR: Attribute number 62 (vendor ) is not defined
in y
our dictionary
---/Errors---
Though tyhis is probably a sql/platypus problem i thought some one might
have had this or a similar problem, thanks
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
(941) 332.4900
http://www.neosmart.com
===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.
currently
running Win2k/Radiator and Sql7/Platypus, If anyone has had these problems
or anyone knows where i can find the solution it would greatly help.
Thanks in advance, if you need any additional information, please let me
know and ill be sure to make a prompt reply.
Kelly Hamlin
[EMAIL PROTECTED
According to Boardtown (Platypus) if the attributres live within Radiatior
you can use them with the account types that live within RadiusNT setup...
just what i heard, i think this would be great! Im sure other are having
this situation..
Kelly Hamlin
[EMAIL PROTECTED]
Network Administrator
12 matches