Hey guys... sorry if my previous message went through... my connection to the house
(and my normal mutt mailer) is down, and I'm having to use work's web-based email.
Anyhow... long story short, we're trying to get AuthBy SQL working with MS-SQL 2000
(running on the same machine with Radiator,
ssage --
From: " Justin Scott" <[EMAIL PROTECTED]>
Reply-To: <[EMAIL PROTECTED]>
Date: Tue, 15 Jan 2002 11:49:38 -0600
>Hey guys... sorry if my previous message went through... my connection to the house
>(and my normal mutt mailer) is down, and I'
I know that Window's DUN dialer etc cannot do anything with the Reply-Message, but I'm
wondering this: does that get insert into the PAP ACK/NAK packets?
My client is writing a custom dialer for their services, and they were wondering if
maybe we could send a message or give a clearer error me
Hi guys,
I have another thing I'm trying to wrap my brain around here, that I can't seem to
figure out.
My client's reason for choosing Radiator is so that they can seamlessly integrate it
into their custom billing/accounting package (which is going great!)
However, the billing system needs t
Hi guys,
Here's some wierdness I'm experiencing with Trace 3 set.
These attribs are all defined in the dictionary, and I am using them in my accounting
statements in the config file, but I suspect the error is being generated because in
the dictionary they are all defined as integer types, and
Gents,
I've been thru the last 6 months of archives, and didn't find anything quite like
what's happening to me when I'm trying to use my AddressAllocator SQL setup.
Issue: Client wants to be able to have "hot standby" MAX 4000 chassis in facility
where the PRIs can be moved from one MAX to an
is the AuthByPolicy in your configuration file - it should be
>
> AuthByPolicy ContinueWhileAccept
>
>The way you have it configured (ContinueUntilAccept) you will never call the
>AuthBy DYNADDRESS clause.
>
>hth
>
>Hugh
>
>
>On Tue, 29 Jan 2002 09:09, Justin
Hugh, et. al.,
I'm having an interesting set of issues now that I have Radiator running "like I want
it" :)
Current configuration includes the following:
1) (which is properly configured to handle the extra reply fields
mentioned in the below scenario)
2)
3)
4)
So... That being said:
1)
Gents,
Please pardon me if this has already been addressed on the list. I've not had a chance
to check, and due to time constraints on other projects, I'm being forced to send this
message before doing any more research.
radacct.pl is returning the following error:
Execute failed for 'select U
Gents,
Please disregard the last message. I changed the datatypes to bigint, and the problem
is resolved. Hopefully forever. :)
cheers,
j
===
Archive at http://www.open.com.au/archives/radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe rad
For those who have yet to see the mentioned CERT Advisory yet, here is a copy of the
notification message.
cheers,
j
-- Original Message --
From: CERT Advisory <[EMAIL PROTECTED]>
Date: Mon, 4 Mar 2002 14:43:15 -0500 (EST)
-BEGIN PGP SIGNED MESSAGE