Re: [RADIATOR] reference manual - date stamps

2010-07-22 Thread Martin Edge
Actually, %d, is the right one, it seems. Thanks Martin. From: radiator-boun...@open.com.au [mailto:radiator-boun...@open.com.au] On Behalf Of Martin Edge Sent: Friday, 23 July 2010 1:04 PM To: radiator@open.com.au Subject: [RADIATOR] reference manual - date stamps Hey Guys, Correct me if I&#

[RADIATOR] reference manual - date stamps

2010-07-22 Thread Martin Edge
ay of the month. %i The Timestamp day of the month (2 digits) Thanks Martin. Martin Edge Software Development, Business Analysis, Product Management and Design [cid:image001.jpg@01CB2A67.87FE9E40] Emersion Software Systems Pty Ltd Phone: .. 1300 793 310 Fax: .. 1300 793

(RADIATOR) Modifying the Proxy-State attribute

2003-09-08 Thread Martin Edge
Hey Guys,   I'm trying to find a way to add something in an Access-Request, so implicitly, irrelevant of which host the packet gets forwarded to, we see the same value in the reply.   The only thoughts I can come up with, as add something symbolic to the end of the Proxy-State attribute.   H

(RADIATOR) Retries - Could be a silly question

2003-08-14 Thread Martin Edge
Hey Guys,   Retries 0 , AuthRADIUS   Retry never, or retry forever?   Martin  

RE: (RADIATOR) Using UseExtendedId

2003-06-19 Thread Martin Edge
Have 1 instance of MacRadius, one of ICRadius 0.18, one X-Radius 1.2.1 which I've never heard of. -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Martin Edge Sent: Thursday, 19 June 2003 5:31 PM To: 'Hugh Irvine' Cc: [EMAIL PROTECTED]; [

RE: (RADIATOR) Using UseExtendedId

2003-06-19 Thread Martin Edge
I'll see I can find out which products these customers are using.. (pretty sure it's not Radiator) Thanks Martin ________ Martin Edge Senior Applications Engineer [EMAIL PROTECTED] KBS Internet Pty Ltd Phone: 1300 302 134 Phone: +61 3 9868

RE: (RADIATOR) Using UseExtendedId

2003-06-19 Thread Martin Edge
[EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Martin Edge Sent: Thursday, 19 June 2003 5:02 PM To: 'Mike McCauley'; 'Hugh Irvine' Cc: [EMAIL PROTECTED] Subject: RE: (RADIATOR) Using UseExtendedId Thanks, I'll give it a bash.. Martin -Original Message

RE: (RADIATOR) Using UseExtendedId

2003-06-19 Thread Martin Edge
Thanks, I'll give it a bash.. Martin -Original Message- From: Mike McCauley [mailto:[EMAIL PROTECTED] Sent: Thursday, 19 June 2003 4:57 PM To: Hugh Irvine; Martin Edge Cc: [EMAIL PROTECTED] Subject: Re: (RADIATOR) Using UseExtendedId Hello Martin, On Thu, 19 Jun 2003 04:38 pm,

RE: (RADIATOR) Using UseExtendedId

2003-06-19 Thread Martin Edge
lt;130>;{`<21><226>+{U<133><140><6> Attributes: Thu Jun 19 16:57:53 2003: WARNING: Unknown reply received in AuthRADIUS for request 74 from 202.4.30.2:1646 Thanks Martin Martin Edge Senior Applications Engineer [EMAIL PROTECTED] KBS Internet Pty Ltd Phone: 1300

(RADIATOR) Using UseExtendedId

2003-06-18 Thread Martin Edge
Title: Message Hey Guys,   Having a few issues after implementing UseExtendedId in our network, much like your documentation suggests, it all works fine except when we have a customer that doesn't support it within their RADIUS system.   Do you know whether UseExtendedId will work as a row

(RADIATOR) Handler for capturing 151 at the end of the Called-Station-Id

2003-03-30 Thread Martin Edge
Martin Edge   Martin EdgeSystems/Applications EngineerKBS InternetPh: 1300 727 205Web: http://www.kbs.net.au/Wholesale: http://xray.kbs.net.au/Email: [EMAIL PROTECTED]

(RADIATOR) Question on FailurePolicy within SQLRADIUS

2002-11-05 Thread Martin Edge
ecific and would be best hiding in it's own AuthBy Module ? Hope I'm not being too confusing :-) Regards, Martin Edge Software/Network Engineer KBS Internet Phone: 1300 727 205 Web: http://www.kbs.net.au/ Extranet: http://xray.kbs.net.au/ eMail: [EMAIL PROTECTED] -=-=-=-

(RADIATOR) using the already connected DB refs

2002-10-28 Thread Martin Edge
&main::log($main::LOG_DEBUG,"Resolved Packet to POPid $popid"); } else { &main::log($main::LOG_DEBUG,"No POPid for NASIP $nasip"); &main::setVariable("popid", "0"); }

(RADIATOR) Bug

2002-10-23 Thread Martin Edge
te as there is no debugging to hint at what the problem was. As soon as TimeDate was installed, it was successful. Regards, Martin Edge Software/Network Engineer KBS Internet Phone: 1300 727 205 Web: http://www.kbs.net.au/ Extranet: http://xray.kbs.net.au/ eMail: [EMAIL PROT

RE: (RADIATOR) Problem with SNMP communities

2002-10-08 Thread Martin Edge
Hey Ganbold, Try this - Usage: snmpget [-Cf] [options...] {} [ ...] My SNMPGet is from UCD-SNMP version 4.2.4 Martin > -Original Message- > From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On > Behalf Of Mike McCauley > Sent: Wednesday, October 09, 2002 2:06 PM > To: [EMAIL PROTECTED

RE: (RADIATOR) Handler working now.... but ;-)

2002-09-19 Thread Martin Edge
Won't this ignore any normal accounting packets? Normal dialup accounting packets are Async, too Skeeve, do you have a separate config/handler for Static IP ports? - Static IP Packet Fri Sep 20 14:00:27 2002: DEBUG: Packet dump: *** Sending to 203.25.159.1 p

RE: (RADIATOR) hostslect FAILUREPOLICY bug!

2002-09-11 Thread Martin Edge
Yeah, this is the similar effect I have seen as well. For instance, it was falling back to the default defined AuthBy RADIUS within SQL RADIUS, after NumHosts was reached, instead of adhering to the selected Failure Policy. If there was not one defined, it simply ignored. This is what made me ne

RE: (RADIATOR) FW: As requested.

2002-09-05 Thread Martin Edge
for each RADIUS box that the Supplier has? Thanks, Martin -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Hugh Irvine Sent: Friday, September 06, 2002 10:35 AM To: Martin Edge Cc: Radiator Subject: Re: (RADIATOR) FW: As requested. Hello Martin - RFC

RE: (RADIATOR) FW: As requested.

2002-09-05 Thread Martin Edge
PROTECTED]]On Behalf Of Hugh Irvine Sent: Friday, September 06, 2002 10:13 AM To: Martin Edge Cc: Radiator Subject: Re: (RADIATOR) FW: As requested. Hello Martin - As Toomas mentioned (thanks Toomas), it is the Identifier 167 that is used to detect duplicates during the DupInterval that is

RE: (RADIATOR) FW: As requested.

2002-09-05 Thread Martin Edge
0:13 AM To: Martin Edge Cc: Radiator Subject: Re: (RADIATOR) FW: As requested. Hello Martin - As Toomas mentioned (thanks Toomas), it is the Identifier 167 that is used to detect duplicates during the DupInterval that is defined for this Client. The DupInterval is a sliding window in time within which

(RADIATOR) FW: As requested.

2002-09-04 Thread Martin Edge
Hey Guys, On what conditions does a packet appear to Radiator as Duplicate? Below I attach two RADIUS packets I received, within 1 second of each other. Of course, the second packet was said to be duplicated, but the packets themselves would show they are completely different.. Thanks, Martin :

(RADIATOR) Creating an Identifier for StatsLogSQL within SQLRADIUS

2002-09-04 Thread Martin Edge
Hey Guys, Can one of my columns i define in HostColumnDef in SQLRADIUS be: - Identifier ? (preferably) - Realm ? (And therefore, would Radiator keep Statistics on each of those identifiers/realms?) Thanks, Martin === Archive at http://www.open.com.au/archives/radiator/ Announcements on [EMAIL

RE: (RADIATOR) Hacking around an upstream issue.

2002-09-04 Thread Martin Edge
ve > packet triggers a delete/insert .. for all intensive purposes > I see a dead > session, which was actually already closed off. > > Thanks > Martin > > -Original Message- > From: Hugh Irvine [mailto:[EMAIL PROTECTED]] > Sent: Wednesday, September 04, 2002

RE: (RADIATOR) Hacking around an upstream issue.

2002-09-03 Thread Martin Edge
Wednesday, September 04, 2002 9:50 AM To: Martin Edge Cc: Radiator Subject: Re: (RADIATOR) Hacking around an upstream issue. Hello Martin - What exactly is the problem? If you just want special processing for Alives, do something like this: regards Hugh On Wednesday, Septemb

(RADIATOR) Hacking around an upstream issue.

2002-09-03 Thread Martin Edge
Hey Guys, Want to see if anyone has any ideas of how I should deal with this situation. We are currently getting the following for the 'occasional' user session from our Upstream RADIUS.. Order Amount Type - 1 1 Start 2

FW: (RADIATOR) NumHosts in SQLRadius

2002-08-28 Thread Martin Edge
# However, the first time we try to find a host for this # instance, we should check whether there is a NumHostQuery (to # confirm the amount of hosts) # Added by Martin Edge <[EMAIL PROTECTED]> if (defined $self->{NumHostQuery}) # If there is a NumHostQuery defined if

RE: (RADIATOR) FW: Comindico DialIP Ports

2002-08-26 Thread Martin Edge
Hi Skeeve, What you may notice, is these packets also contain the attribute "Tunnel-Id" These attributes will match the two packets, perhaps you could use that in order to collect the two packets correctly. I have to battle that one myself in a few days, I have suggested to COMindico engineers t

RE: (RADIATOR) Determine IP address request came to

2002-08-25 Thread Martin Edge
Ah, re-reading, I now understand your query .. Not in the list I have of attributes, anyhow.. -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Martin Edge Sent: Monday, August 26, 2002 9:07 AM To: Timothy G. Wells; [EMAIL PROTECTED] Subject: RE

RE: (RADIATOR) Determine IP address request came to

2002-08-25 Thread Martin Edge
I think %c.. Check the docco -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Timothy G. Wells Sent: Sunday, August 25, 2002 10:29 PM To: [EMAIL PROTECTED] Subject: (RADIATOR) Determine IP address request came to Greetings, Has there been anything adde

RE: (RADIATOR) NumHosts in SQLRadius

2002-08-20 Thread Martin Edge
ator to figure out how many RADIUS targets maximum it had to deal with.. ? Stats: Yeah Cool :) Thanks, Martin -Original Message- From: Hugh Irvine [mailto:[EMAIL PROTECTED]] Sent: Tuesday, August 20, 2002 5:27 PM To: Martin Edge Cc: [EMAIL PROTECTED] Subject: Re: (RADIATOR) NumHosts in SQLRa

(RADIATOR) NumHosts in SQLRadius

2002-08-19 Thread Martin Edge
Hey Guys, Is there anyway to set NumHosts dynamically? Say perhaps via the first SQLRADIUS lookup, it returns the NumHosts variable? I'd prefer to not have to hard set this, as I'm trying to design the system around a dynamic number of destination RADIUS servers.. also.. What type of detail ca

(RADIATOR) Question about Radius and SQL

2002-01-24 Thread Martin Edge
:58 2002 32217: ERR: Execute failed for 'Sp_fetchUserPassword 'shields'': SQL TimeoutFri Jan 25 17:44:00 2002 532429: ERR: Execute failed for 'Sp_fetchUserPassword 'blp04395'': SQL TimeoutFri Jan 25 17:44:02 2002 832373: ERR: Execute failed for 'Sp_fetchUserPassw -Martin Edge Technical Services Co-ordinator Phoneware Online eMail: [EMAIL PROTECTED] Phone: +613 9640 4140 ext. 193   "In the end, it's speed, price and customer service." -  

RE: (RADIATOR) (Radiator) SNMPAgent on NT4?

2002-01-23 Thread Martin Edge
Believe you need SNMP_Session-0.90 Should be avaliable from CPAN Martin -Original Message- From: Kent, Ashley [mailto:[EMAIL PROTECTED]] Sent: Thursday, 24 January 2002 11:32 AM To: '[EMAIL PROTECTED]' Subject: (RADIATOR) (Radiator) SNMPAgent on NT4? Guys, I want to start doing mrtg

(RADIATOR) Odd Issue with SNMPAgent

2002-01-20 Thread Martin Edge
ng to everything, instead of the IP it was told to bind too..   Using SNMP_Session-0.90 + Radiator 2.19   Has this been seen before? Martin   -Martin Edge Technical Services Co-ordinator Phoneware Online eMail: [EMAIL PROTECTED] Phone: +613 9640 4140 ext. 193

(RADIATOR) Stopping processing on Invalid radius requests

2001-10-25 Thread Martin Edge
Call-Arrived-time = 183605368 Call-Lost-time = 183605388 Thanks, Martin - Martin Edge Network Engineer Phoneware Online eMail: <mailto:[EMAIL PROTECTED]> [EMAIL PROTECTED] Phone: +613 9640 4140 ext. 193 "Creating the structure necessary for

(RADIATOR) Rewriting Usernames on the Fly

2001-10-22 Thread Martin Edge
;$username'"); #&main::log($main::LOG_DEBUG, "my alternative username $username translates to $results[0]->[0]"); # Find the new username $p->change_attr('User-Name', $results[0]->[0]);