On Sun, 1 Dec 2024 at 07:11, Stafford Horne wrote:
>
> From: Ahmad Fatoum
>
> We used to only have a single UART on the platform and it was located at
> address 0x9000. When the number of UARTs was increased to 4, the
> first UART remained at it's location, but instead of being the first one
From: Ahmad Fatoum
We used to only have a single UART on the platform and it was located at
address 0x9000. When the number of UARTs was increased to 4, the
first UART remained at it's location, but instead of being the first one
to be registered, it became the last.
This caused QEMU to pick