On Fri, Mar 23, 2012 at 3:52 AM, Sebastian Melchior wrote:
> unfortunately we cannot directly control the TRIM (i am not sure it even
> occurs) because the SSDs are behind an LSI MegaSAS 9260 Controller which does
> not allow access via smart. Even if some kind of TRIM command is the problem,
>
On Mon, May 7, 2012 at 4:25 PM, Thomas Kellerer wrote:
> That seems to be a documentation bug.
> I tried it, and it definitely does not work (or I am missing something).
Apparently I am the one who is missing something. :-)
> Their release notes at:
> http://www.oracle.com/technetwork/developer-