Re: [GENERAL] Invalid data read from synchronously replicated hot standby

2016-05-11 Thread Kevin Grittner
On Wed, May 11, 2016 at 5:44 AM, wrote: >> We are getting invalid data when reading from a synchronously >> replicated hot standby node in a 2-node setup. To better understand >> the situation, we have created a document that provides an overview. >> We are hoping that someone might be able to co

Re: [GENERAL] Invalid data read from synchronously replicated hot standby

2016-05-11 Thread martin . kamp . jensen
Sameer Kumar wrote on 04/21/2016 13:56:52: > From: Sameer Kumar > To: Martin Kamp Jensen/DK/Schneider@Europe, pgsql-general@postgresql.org > Date: 04/21/2016 14:00 > Subject: Re: [GENERAL] Invalid data read from synchronously > replicated hot standby > > > O

Re: [GENERAL] Invalid data read from synchronously replicated hot standby

2016-04-26 Thread martin . kamp . jensen
Adrian Klaver wrote on 04/21/2016 16:03:55: > From: Adrian Klaver > To: Martin Kamp Jensen/DK/Schneider@Europe, pgsql-general@postgresql.org > Date: 04/21/2016 16:09 > Subject: Re: [GENERAL] Invalid data read from synchronously > replicated hot standby > > O

Re: [GENERAL] Invalid data read from synchronously replicated hot standby

2016-04-21 Thread Adrian Klaver
On 04/21/2016 01:05 AM, martin.kamp.jen...@schneider-electric.com wrote: Hi, We are getting invalid data when reading from a synchronously replicated hot standby node in a 2-node setup. To better understand the situation, we have created a document that provides an overview. We are hoping that s

Re: [GENERAL] Invalid data read from synchronously replicated hot standby

2016-04-21 Thread Sameer Kumar
On Thu, 21 Apr 2016 04:05 , wrote: > Hi, > > We are getting invalid data when reading from a synchronously replicated > hot standby node in a 2-node setup. To better understand the situation, we > have created a document that provides an overview. We are hoping that > someone might be able to con

[GENERAL] Invalid data read from synchronously replicated hot standby

2016-04-21 Thread martin . kamp . jensen
Hi, We are getting invalid data when reading from a synchronously replicated hot standby node in a 2-node setup. To better understand the situation, we have created a document that provides an overview. We are hoping that someone might be able to confirm whether or not the setup makes sense, i