Re: [solved] Setting up streaming replication problems

2018-01-31 Thread Thiemo Kellner
On 01/31/18 13:26, Thiemo Kellner wrote: master by pg_basebackup. This lead to the error of unequal identifier error. Maybe I was not reading carefully enough, however, I was not sure Addendum: The error shows up in the standby log. -- +49 (0)1578-772 37 37 +41 (0)78 947 36 21 SIP/iptel.org:

Re: [solved] Setting up streaming replication problems

2018-01-31 Thread Thiemo Kellner
Oh, I forgot again already. *shame on me* I tried to set up streaming replication without cloning standby from the master by pg_basebackup. This lead to the error of unequal identifier error. Maybe I was not reading carefully enough, however, I was not sure what to do with the created files an

Re: [solved] Setting up streaming replication problems

2018-01-31 Thread Thiemo Kellner
Andreas Kretschmer and others of the german mailing list put me on the right track again. My working config changes from standard is as listed below. My problem was, that application_name in primary_conninfo of the standby was missing. This lead the master not to recognise standby having taken