the other should not wait that time.
>
> ** **
>
> Regards, Christian
>
> ** **
>
> *From:* Andrew Beekhof [mailto:and...@beekhof.net]
> *Sent:* Dienstag, 05. Juli 2011 03:46
>
> *To:* The Pacemaker cluster resource manager
> *Subject:* Re: [Pacem
egards, Christian
From: Andrew Beekhof [mailto:and...@beekhof.net<mailto:and...@beekhof.net>]
Sent: Freitag, 01. Juli 2011 09:31
To: The Pacemaker cluster resource manager
Subject: Re: [Pacemaker] Group not started/stopped in correct order with -INF
collocation
On Tue, May 31, 2011 at 10:05
that
should be observed?
>
>
> Regards, Christian
>
> ** **
>
> *From:* Andrew Beekhof [mailto:and...@beekhof.net]
> *Sent:* Freitag, 01. Juli 2011 09:31
>
> *To:* The Pacemaker cluster resource manager
> *Subject:* Re: [Pacemaker] Group not
Hello Andrew,
No, there are no ordering constraint between the groups!
Regards, Christian
From: Andrew Beekhof [mailto:and...@beekhof.net]
Sent: Freitag, 01. Juli 2011 09:31
To: The Pacemaker cluster resource manager
Subject: Re: [Pacemaker] Group not started/stopped in correct order with -INF
On Tue, May 31, 2011 at 10:05 PM, Kulovits Christian - OS ITSC <
christian.kulov...@austrian.com> wrote:
> Hello,
>
> In a 2-node cluster two groups (prod, test) are defined with a collocation
> score=“-INFINITY“. When the node running the group prod failed, the test
> group on the other node
On 2011-05-31 16:04, Kulovits Christian - OS ITSC wrote:
> Sorry!! Yes, of course
>
> Corosync Cluster Engine, version '1.2.7' SVN revision '3008'
> CRM Version: 1.0.9 (da7075976b5ff0bee71074385f8fd02f296ec8a3)
> pacemaker 1.0.10-1.2.el5 - (none) x86_64
> corosync 1.2.7-1.1
: Mittwoch, 01. Juni 2011 10:21
To: The Pacemaker cluster resource manager
Subject: Re: [Pacemaker] Group not started/stopped in correct order with -INF
collocation
On 2011-05-31 16:04, Kulovits Christian - OS ITSC wrote:
> Sorry!! Yes, of course
>
> Corosync Cluster Engine, version
On 2011-05-31 16:04, Kulovits Christian - OS ITSC wrote:
> Sorry!! Yes, of course
>
> Corosync Cluster Engine, version '1.2.7' SVN revision '3008'
> CRM Version: 1.0.9 (da7075976b5ff0bee71074385f8fd02f296ec8a3)
> pacemaker 1.0.10-1.2.el5 - (none) x86_64
> corosync 1.2.7-1.1
2
And it is a 4-node cluster...
Regards, Christian
-Original Message-
From: Florian Haas [mailto:florian.h...@linbit.com]
Sent: Dienstag, 31. Mai 2011 14:41
To: The Pacemaker cluster resource manager
Subject: Re: [Pacemaker] Group not started/stopped in correct order with -INF
collocati
On 2011-05-31 14:05, Kulovits Christian - OS ITSC wrote:
> Hello,
>
> In a 2-node cluster two groups (prod, test) are defined with a
> collocation score=“-INFINITY“. When the node running the group prod
> failed, the test group on the other node was stopped and the prod group
> was started. After
10 matches