Re: [Pacemaker] inconsistence in crm_mon and crm resource show

2012-03-25 Thread Lars Marowsky-Bree
On 2012-03-21T16:48:45, "Janec, Jozef" wrote: > Fixed now, > > By mistake I removed property stonith-enabled=false, and therefore the second > node always tried fence the second node which crashed/was rebooted. Result > was that all resources were down and waiting till fence will return done.

Re: [Pacemaker] inconsistence in crm_mon and crm resource show

2012-03-21 Thread Janec, Jozef
as expected, resources are started on the second node without fence wait Best regards Jozef -Original Message- From: Janec, Jozef Sent: Wednesday, March 21, 2012 11:47 AM To: The Pacemaker cluster resource manager Subject: Re: [Pacemaker] inconsistence in crm_mon and crm resource show

Re: [Pacemaker] inconsistence in crm_mon and crm resource show

2012-03-21 Thread Janec, Jozef
> > On 2012-03-21T09:42:26, "Janec, Jozef" wrote: > > > Node b300ple0: UNCLEAN (offline) > > rs_nw_dbjj7 (ocf::heartbeat:IPaddr) Started > > rs_nw_cijj7 (ocf::heartbeat:IPaddr) Started > > Node b400ple0: online > > sbd_fense_SHARED2 (stonith:external/sbd) St

Re: [Pacemaker] inconsistence in crm_mon and crm resource show

2012-03-21 Thread Lars Marowsky-Bree
On 2012-03-21T09:42:26, "Janec, Jozef" wrote: > Node b300ple0: UNCLEAN (offline) > rs_nw_dbjj7 (ocf::heartbeat:IPaddr) Started > rs_nw_cijj7 (ocf::heartbeat:IPaddr) Started > Node b400ple0: online > sbd_fense_SHARED2 (stonith:external/sbd) Started > > Inacti

[Pacemaker] inconsistence in crm_mon and crm resource show

2012-03-21 Thread Janec, Jozef
Hello All, I have easy configuration of 2 node cluster: b400ple0:(/root/home/root)(root)#crm configure show node b300ple0 node b400ple0 primitive rs_nw_cijj7 ocf:heartbeat:IPaddr \ operations $id="rs_nw_cijj7-operations" \ op monitor interval="5s" timeout="20s" \ params ip