Re: [Pacemaker] Stonith Device APC AP7900

2010-11-20 Thread Rick Cone
Dejan, Well, I will got back to plan B and use the power splitter. Thanks, Rick -Original Message- From: Dejan Muhamedagic [mailto:deja...@fastmail.fm] Sent: Tuesday, November 16, 2010 3:24 AM To: The Pacemaker cluster resource manager Subject: Re: [Pacemaker] Stonith Device APC

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-19 Thread Rick Cone
, November 17, 2010 4:01 PM To: pacemaker@oss.clusterlabs.org Subject: Re: [Pacemaker] Stonith Device APC AP7900 > Message: 3 > Date: Tue, 16 Nov 2010 11:24:26 +0100 > From: Dejan Muhamedagic > To: The Pacemaker cluster resource manager > > Subject: Re: [Pacemaker] Stonith

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-19 Thread Dejan Muhamedagic
Hi, On Thu, Nov 18, 2010 at 06:45:01AM +0200, Chris Picton wrote: > > > On 2010/11/18 1:01 AM, Andrew Daugherity wrote: > In production I am planning to have 2 separate AP7900 units each plugged > into 2 different APC UPS units to achieve that. I would then have the > single node name

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-19 Thread Dejan Muhamedagic
Hi, On Wed, Nov 17, 2010 at 05:01:20PM -0600, Andrew Daugherity wrote: > > Message: 3 > > Date: Tue, 16 Nov 2010 11:24:26 +0100 > > From: Dejan Muhamedagic > > To: The Pacemaker cluster resource manager > > > > Subject: Re: [Pacemaker] Ston

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-18 Thread Rick Cone
Chris, That would be great if you could pass those on to me. Thank you, Rick -Original Message- From: Chris Picton [mailto:ch...@ecntelecoms.com] Sent: Wednesday, November 17, 2010 9:45 PM To: pacema...@clusterlabs.org Subject: Re: [Pacemaker] Stonith Device APC AP7900 On 2010/11

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-17 Thread Chris Picton
On 2010/11/18 1:01 AM, Andrew Daugherity wrote: In production I am planning to have 2 separate AP7900 units each plugged into 2 different APC UPS units to achieve that. I would then have the single node name on each, for each of the 2 PS's on the individual systems. ... Right, there's curren

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-17 Thread Andrew Daugherity
> Message: 3 > Date: Tue, 16 Nov 2010 11:24:26 +0100 > From: Dejan Muhamedagic > To: The Pacemaker cluster resource manager > > Subject: Re: [Pacemaker] Stonith Device APC AP7900 > Message-ID: <20101116102426.ga22...@rondo.homenet> > Content-Type: text/p

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-16 Thread Dejan Muhamedagic
Hi, On Mon, Nov 15, 2010 at 10:41:22AM -0700, Devin Reade wrote: > --On Monday, November 15, 2010 08:40:45 AM -0700 Rick Cone > wrote: > > > In production I am planning to have 2 separate AP7900 units each plugged > > into 2 different APC UPS units to achieve that. I would then have the > > sin

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-15 Thread Rick Cone
Reade [mailto:g...@gno.org] Sent: Monday, November 15, 2010 10:41 AM To: pacemaker@oss.clusterlabs.org Subject: Re: [Pacemaker] Stonith Device APC AP7900 --On Monday, November 15, 2010 08:40:45 AM -0700 Rick Cone wrote: > In production I am planning to have 2 separate AP7900 units each plugged

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-15 Thread Devin Reade
--On Monday, November 15, 2010 08:40:45 AM -0700 Rick Cone wrote: > In production I am planning to have 2 separate AP7900 units each plugged > into 2 different APC UPS units to achieve that. I would then have the > single node name on each, for each of the 2 PS's on the individual > systems. So

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-15 Thread Rick Cone
..@gno.org] Sent: Sunday, November 14, 2010 9:32 PM To: pacemaker@oss.clusterlabs.org Subject: Re: [Pacemaker] Stonith Device APC AP7900 Rick Cone wrote: > Perhaps I'll just use 1 outlet with the node name, > with a power splitter to the 2 redundant power supplies to reduce the > c

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-15 Thread Dejan Muhamedagic
Hi, On Sun, Nov 14, 2010 at 09:32:06PM -0700, Devin Reade wrote: > Rick Cone wrote: > > > Perhaps I'll just use 1 outlet with the node name, > > with a power splitter to the 2 redundant power supplies to reduce the > > chances of problems. > > IMO, if you're going to use a chassis with redundan

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-14 Thread Devin Reade
Rick Cone wrote: > Perhaps I'll just use 1 outlet with the node name, > with a power splitter to the 2 redundant power supplies to reduce the > chances of problems. IMO, if you're going to use a chassis with redundant power supplies, you're better off with a system that uses an ALOM/DRAC/iLO, or

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-03 Thread Dejan Muhamedagic
stmail.fm] > Sent: Thursday, October 28, 2010 9:16 AM > To: rc...@securepaymentsystems.com; The Pacemaker cluster resource manager > Subject: Re: [Pacemaker] Stonith Device APC AP7900 > > Hi, > > On Thu, Oct 28, 2010 at 08:35:30AM -0600, Rick Cone wrote: > > Dejan, > &

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-02 Thread Rick Cone
wer supplies to reduce the chances of problems. Rick -Original Message- From: Dejan Muhamedagic [mailto:deja...@fastmail.fm] Sent: Thursday, October 28, 2010 9:16 AM To: rc...@securepaymentsystems.com; The Pacemaker cluster resource manager Subject: Re: [Pacemaker] Stonith Device APC AP79

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-02 Thread Pavlos Parissis
On 2 November 2010 12:58, Dejan Muhamedagic wrote: [...snip...] > > > Do you know under which conditions pacemaker initiates multiple > connections > > to a fencing device? > > There are no specific conditions. It can happen by chance because > individual clone instances run independently. > >

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-02 Thread Dejan Muhamedagic
Hi, On Tue, Nov 02, 2010 at 12:10:37PM +0100, Pavlos Parissis wrote: > On 2 November 2010 11:04, Dejan Muhamedagic wrote: > > > Hi, > > > > On Tue, Nov 02, 2010 at 08:08:32AM +0100, Pavlos Parissis wrote: > > > On 1 November 2010 15:01, Rick Cone > > wrote: > > > > > > > Dejan, > > > > > > > >

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-02 Thread Pavlos Parissis
On 2 November 2010 11:04, Dejan Muhamedagic wrote: > Hi, > > On Tue, Nov 02, 2010 at 08:08:32AM +0100, Pavlos Parissis wrote: > > On 1 November 2010 15:01, Rick Cone > wrote: > > > > > Dejan, > > > > > > Below I had: > > > > > > primitive res_stonith stonith:apcmastersnmp \ > > > params

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-02 Thread Dejan Muhamedagic
Hi, On Tue, Nov 02, 2010 at 08:08:32AM +0100, Pavlos Parissis wrote: > On 1 November 2010 15:01, Rick Cone wrote: > > > Dejan, > > > > Below I had: > > > > primitive res_stonith stonith:apcmastersnmp \ > > params ipaddr="192.1.1.109" port="161" community="sps" \ > > op start inte

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-02 Thread Pavlos Parissis
On 1 November 2010 15:01, Rick Cone wrote: > Dejan, > > Below I had: > > primitive res_stonith stonith:apcmastersnmp \ > params ipaddr="192.1.1.109" port="161" community="sps" \ > op start interval="0" timeout="60s" \ > op monitor interval="60s" timeout="60s" \ >

Re: [Pacemaker] Stonith Device APC AP7900

2010-11-01 Thread Rick Cone
t look like in the crm configure? What are the pros/cons to this compared to the clone setup I have? Thanks, Rick -Original Message- From: Dejan Muhamedagic [mailto:deja...@fastmail.fm] Sent: Thursday, October 28, 2010 9:16 AM To: rc...@securepaymentsystems.com; The Pacemaker cluste

Re: [Pacemaker] Stonith Device APC AP7900

2010-10-28 Thread Dejan Muhamedagic
something like 2h or so. > op stop interval="0" timeout="60s" > clone rc_res_stonith res_stonith \ > meta target-role="Started" You can also use a single instance setup, i.e. without clones. Thanks, Dejan > Thanks, > Rick > > >

Re: [Pacemaker] Stonith Device APC AP7900

2010-10-28 Thread Rick Cone
t="60s" \ op stop interval="0" timeout="60s" clone rc_res_stonith res_stonith \ meta target-role="Started" Thanks, Rick -Original Message- From: Dejan Muhamedagic [mailto:deja...@fastmail.fm] Sent: Thursday, October 28, 2010 2:37 AM To: &#

Re: [Pacemaker] Stonith Device APC AP7900

2010-10-28 Thread Dejan Muhamedagic
luster resource manager > Subject: Re: [Pacemaker] Stonith Device APC AP7900 > > Hi, > > On Wed, Oct 27, 2010 at 09:11:03AM -0600, Rick Cone wrote: > > I use the APC AP7900 stonith device with apcmastersnmp. It seems to works > > well, but I see the message in logs: