Hi Andrew,
I reported it in Bugzilla. Please confirm it.
* http://bugs.clusterlabs.org/show_bug.cgi?id=5064
Best Regards,
Kazunori INOUE
(12.05.09 16:12), Andrew Beekhof wrote:
On Mon, May 7, 2012 at 7:53 PM, Kazunori INOUE
wrote:
Hi,
I am using Pacemaker-1.1 (devel: db5e167).
When stonith
On Mon, May 7, 2012 at 7:53 PM, Kazunori INOUE
wrote:
> Hi,
>
> I am using Pacemaker-1.1 (devel: db5e167).
> When stonith-enabled is "false", and pacemakerd is terminated abnormally,
> the states differ by whether a node is DC.
>
> - (1-a) pacemakerd of DC node was terminated -> OFFLINE
> - (1
Hi,
I am using Pacemaker-1.1 (devel: db5e167).
When stonith-enabled is "false", and pacemakerd is terminated abnormally,
the states differ by whether a node is DC.
- (1-a) pacemakerd of DC node was terminated -> OFFLINE
- (1-b) pacemakerd of non-DC node was terminated -> UNCLEAN (offline)
Is