quot; \
op stop interval="0" timeout="15" \
op monitor interval="15" timeout="15" start-delay="15" \
meta target-role="started"
group asterisk res_Filesystem_rep res_IPaddr2_northIP res_IPaddr2_sipIP
res_mysqld_re
Hi
Question about the heartbeat links, I have two configured in ha.cf
mcast eth0 239.192.0.0 694 1 0
bcast eth3
but when eth3 was disconnected the cluster tried to failover, is this correct
operation or do both eth0 & eth3 have to down to trigger a failover?
Best Regards,
G
both server so i can startagain?
Regards,
Gerry Kernan
InfinityIT
Suite 17 The Mall,
Beacon court,
Sandyford,
Dublin 18.
p:+353-1-2930090
f:+353-1-2930137
<>___
Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
http://oss.clusterla
Hi Andrew
Thanks for your reply. I got it sorted I has resource fencing enabled in
drbd.conf and forgot to disable the init s script for drbd
Best regards,
Gerry kernan
InfinityIT
On 7 Sep 2010, at 07:22, Andrew Beekhof wrote:
>
>
> On Mon, Sep 6, 2010 at 5:03 PM, Gerry Kernan
op interval="0" timeout="15" \
opmonitor interval="15" timeout="15"start-delay="15" \
metaresource-stickiness="0"
group asterisk res_Filesystem_drbd res_IPaddr2_IPaddrres_asterisk_asterisk
res_httpd_http res_mysqld_mysqlres
: Gerry Kernan; The Pacemaker cluster resource manager
Subject: Re: [Pacemaker] can failover be set to manual
On Thu, Apr 15, 2010 at 6:20 PM, Gerry Kernan wrote:
Hi
Should i still be able to migrate theresources over to the other node?
Nope. All resource management is disabled
Hi
Should i still be able to migrate the resources over to the other node?
Gerry
From: Andrew Beekhof [mailto:and...@beekhof.net]
Sent: 14 April 2010 21:24
To: Gerry Kernan; The Pacemaker cluster resource manager
Subject: Re: [Pacemaker] can failover be set to manual
Sounds like is
Andrew,
Thanks ill try that.
Gerry
From: Andrew Beekhof [mailto:and...@beekhof.net]
Sent: 14 April 2010 21:24
To: Gerry Kernan; The Pacemaker cluster resource manager
Subject: Re: [Pacemaker] can failover be set to manual
Sounds like is-managed-default=false is what you want
On Wed
node doesnt think
that node 1 is down and bring up the resources.
Regards,
Gerry Kernan
InfinityIT
Suite 17 The Mall,
Beacon court,
Sandyford,
Dublin 18.
p:+353-1-2930090
f:+353-1-2930137
<>___
Pacemaker mailing list: Pac
resource manager
Subject: Re: [Pacemaker] disable failover when doing orderly reboot
Hi Gerry,
my poor man's answer is:
Stop all resources running on the node going to be shut down.
That's what you want in the end, isn't it?
Best regards
Andreas Mock
-----
Von: Gerry K
Hi
Is it possible to disable failover when doing an orderly reboot on the primary
node so that the resources dont fail over to the standby node.
Regards,
Gerry Kernan
InfinityIT
Suite 17 The Mall,
Beacon court,
Sandyford,
Dublin 18.
p:+353-1-2930090
f:+353-1-2930137
ocaldomain
location res_creditfs grp_credit inf: host2.localdomain
property $id="cib-bootstrap-options" \
dc-version="1.0.4-6dede86d6105786af3a5321ccf66b44b6914f0aa" \
cluster-infrastructure="openais" \
expected-q
yption
threads:0
# Optionally assign a fixed node id (integer)
# nodeid: 1234
rrp_mode:active
interface {
ringnumber: 0
bindnetaddr: 192.168.200.0
mcastaddr: 239.0.0.42
mcas
13 matches