Xinwei Hu writes:
>
> This sounds a like a fixed issue for SLE11SP1 indeed.
> referring to:
> http://archives.free.net.ph/message/20100309.075255.baa4b2eb.en.html
>
Well it is not fixed with SP1, but with some Patch after SP1 - don`t know which
thou, as the clvmd is the same for SP1 before and
> Any Idea how to solve it?
I created a testscenario with the same conditions ( same OS Sles11 SP1 with HAE
and the CIB from the original cluster ), but with full online update and there
everthing works fine.
So it seems there was a bugfix for that.
On Monday i will try a full update for my orig
Hello all,
first the scenario:
Two Nodes connected to two SANs via fibre channel and
mirrored devices. Multipath Partitons are used.
So i have two disks ( one disk SAN A and one disk SAN B )
combined to let`s say DM-0
Now i create a SBD Partition on the multipath device and
configure the SBD
Hello Pierre,
check out the this link to the novell site:
http://www.novell.com/documentation/sles10/heartbeat/?page=/documentation/sles10/heartbeat/data/man_crmresource.html
it`s for sles 10 thou... maybe it helps
go to manual configuration of a cluster on the left site
and then to configuring
Dear all,
i have a question regarding the ping nodes and the resource ocf:pacemaker:pingd
or ocf:pacemaker:ping
I configured the resource ping on one of my two nodes. Pointing the resource (
to a virtual ip adress i configured with hb_gui. XML:
Now if the stop th