Re: [Pacemaker] CMAN and Pacemaker with IPv6

2014-07-14 Thread Teerapatr Kittiratanachai
Dear Honza, Sorry to say this, but I found new error again. LOL This time, I already install the 1.4.1-17 as your advice. And the nodename, without altname, is map to IPv6 using hosts file. Everything is fine, but the 2 node can't communicate to each other. So I add the multicast address manually

Re: [Pacemaker] CMAN and Pacemaker with IPv6

2014-07-14 Thread Teerapatr Kittiratanachai
Honza Great, Thank you very much. But the terrible thing for me is I'm using the package from OpenSUSE repo. When i turn back to CentOS repo, which store lower version, the Dependency problem has occurred. Anyway, thank you for your help. Teenigma On Mon, Jul 14, 2014 at 8:51 PM, Jan Friesse

Re: [Pacemaker] crm commands are blocked by starting services

2014-07-14 Thread Andrew Beekhof
On 14 Jul 2014, at 7:01 pm, Johan Huysmans wrote: > Hi All, > > I noticed that any changes made with crm are not applied to the cluster > configuration when a resource is being started. > > I have a resource which can take some time to be started (2minutes). Whenever > such resource is start

Re: [Pacemaker] pacemaker stonith No such device

2014-07-14 Thread Dvorak Andreas
Hi Thank you very much, I did not see that mistake. Now it does work. Best regards, Andreas -Ursprüngliche Nachricht- Von: Andrew Beekhof [mailto:and...@beekhof.net] Gesendet: Montag, 14. Juli 2014 14:25 An: The Pacemaker cluster resource manager Betreff: Re: [Pacemaker] pacemaker ston

Re: [Pacemaker] CMAN and Pacemaker with IPv6

2014-07-14 Thread Jan Friesse
Honza, How do I include the patch with my CentOS package? Do I need to compile them manually? Yes. Also official CentOS version was never 1.4.5. If you are using CentOS, just use stock 1.4.1-17.1. Patch is included there. Honza TeEniGMa On Mon, Jul 14, 2014 at 3:21 PM, Jan Friesse wrote

Re: [Pacemaker] pacemaker stonith No such device

2014-07-14 Thread Andrew Beekhof
On 14 Jul 2014, at 10:09 pm, Dvorak Andreas wrote: > Hi, > > thank you for you answer, here is the creatation of the fancing resources: > pcs stonith create ipmi-fencing-sv2827 fence_ipmilan pcmk_host_list="sv2827" > ipaddr=10.110.28.27 action="off" login=ipmi passwd=X delay=15 op monitor

Re: [Pacemaker] pacemaker stonith No such device

2014-07-14 Thread Dvorak Andreas
Hi, thank you for you answer, here is the creatation of the fancing resources: pcs stonith create ipmi-fencing-sv2827 fence_ipmilan pcmk_host_list="sv2827" ipaddr=10.110.28.27 action="off" login=ipmi passwd=X delay=15 op monitor interval=60s pcs stonith create ipmi-fencing-sv2828 fence_ipmil

Re: [Pacemaker] CMAN and Pacemaker with IPv6

2014-07-14 Thread Teerapatr Kittiratanachai
Honza, How do I include the patch with my CentOS package? Do I need to compile them manually? TeEniGMa On Mon, Jul 14, 2014 at 3:21 PM, Jan Friesse wrote: > Teerapatr, > > >> For more information, >> >> >> these are LOG from /var/log/messages >> ... >> Jul 14 10:28:07 wh00 kernel: : DLM (built

[Pacemaker] Invisible dependency (at least to me)

2014-07-14 Thread Robert Dahlem
Hi, I have this configuration (minus the stonith resources and stuff on other nodes for brevity): node korfwf01 node korfwf02 rsc_template template-DRBD ocf:linbit:drbd \ op start interval="0" timeout="240" \

Re: [Pacemaker] is_managed meta attribute on suse 10 with heartbeat + pacemaker

2014-07-14 Thread emmanuel segura
Thanks Lars, I took the command from man page, "Disabling a resource management for a resource in the CRM crm_resource -p is_managed -r my_first_ip -t primitive -v off " I think the man pages is wrong, because is missing the --meta parameter 2014-07-12 20:36 GMT+02:00 Lars Marowsky

[Pacemaker] crm commands are blocked by starting services

2014-07-14 Thread Johan Huysmans
Hi All, I noticed that any changes made with crm are not applied to the cluster configuration when a resource is being started. I have a resource which can take some time to be started (2minutes). Whenever such resource is started any change made by executing the crm command is hold until th

Re: [Pacemaker] CMAN and Pacemaker with IPv6

2014-07-14 Thread Jan Friesse
Teerapatr, > For more information, these are LOG from /var/log/messages ... Jul 14 10:28:07 wh00 kernel: : DLM (built Mar 25 2014 20:01:13) installed Jul 14 10:28:07 wh00 corosync[2716]: [MAIN ] Corosync Cluster Engine ('1.4.5'): started and ready to provide service. Jul 14 10:28:07 wh00 cor