Hi All,
Can someone please help me in below scenario:
I want my daemon running on 2 nodes to be monitored using HB+pacemaker.
The daemon is already running before the RA is configured using crm,
#crm configure primitive my_daemon lsb::testd meta allow-migrate="true"
is-managed="false" migration-
I pulled the git tree but it failed to build in a number of ways when
trying to build on centos 5.9.
make rpm-dep:
Checking for new repos for mirrors
Enabling epel-source repository
Enabling rpmfusion-free-updates-testing-source repository
No such package(s): pacemaker-fedora.spec.src
make: *
On 05/06/2013, at 8:59 PM, Andreas Mock wrote:
> Hi Andrew,
>
> waiting for the RHEL 6.x build of pacemaker 1.1.10 I want to ask
> whether there can be done something for finding the memory leaks.
> If so, than explain the steps needed in detail. Currently there
> are two real clusters availabl
On 06/06/2013, at 4:44 AM, Michael Schwartzkopff wrote:
> Hi,
>
> I was not satisfied with the situation that the utilization of resources is
> static. This is not how real world resources behave. Especially virtual
> guests in a clustered environment show daily load patterns. So I thought i
Hi,
I was not satisfied with the situation that the utilization of resources is
static. This is not how real world resources behave. Especially virtual guests
in a clustered environment show daily load patterns. So I thought it would be
a good idea to make the utilization of resources dynamic.
I'm using dnsmasq as an LSB resource to provide a cluster dns server. I
have a resource group that contains the floating ip address and the
dnsmasq resource so they move together.
I have not tried to use BIND.
-Gregg Stock
On 6/5/2013 11:30 AM, paul wrote:
Hi. I have followed the Clusters fro
Hi Guys,
one question about group resource for starting parallel configuring with
crmshell (Scientific Linux 64
with pacemaker 1.1.8-7, cman-3.0.12.1-49 and crmsh-1.2.5-55).
in my 2 node cluster I´ll configured a group with 40 ip-address resources for
easy managing. Now I want that
start the r
- Original Message -
> From: "Serge Dubrouski"
> To: "The Pacemaker cluster resource manager"
> Sent: Wednesday, June 5, 2013 9:27:15 AM
> Subject: Re: [Pacemaker] named
>
>
>
>
> There should be an OCF version of named RA available in resource
> agents package.
> On Jun 5, 2013 5:45
There should be an OCF version of named RA available in resource agents
package.
On Jun 5, 2013 5:45 AM, "David Coulson" wrote:
>
> On 6/5/13 2:30 PM, paul wrote:
>
>> Hi. I have followed the Clusters from scratch PDF and have a working two
>> node active passive cluster with ClusterIP, WebDataCl
On 6/5/13 2:30 PM, paul wrote:
Hi. I have followed the Clusters from scratch PDF and have a working two
node active passive cluster with ClusterIP, WebDataClone,WebFS and
WebSite working. I am using BIND DNS to direct my websites to the
cluster address. When I perform a failover which works ok I
On 6/5/13 14:59 , Andreas Mock wrote:
Hi Andrew,
waiting for the RHEL 6.x build of pacemaker 1.1.10 I want to ask
whether there can be done something for finding the memory leaks.
If so, than explain the steps needed in detail. Currently there
are two real clusters available to do testing.
(Que
Hi Andrew,
waiting for the RHEL 6.x build of pacemaker 1.1.10 I want to ask
whether there can be done something for finding the memory leaks.
If so, than explain the steps needed in detail. Currently there
are two real clusters available to do testing.
(Questions: Do you need logs? Debug-Log? Som
thanks for your answer.
i was next to the solution: need root:exim 775 for the symlink.target.
after `chown root.mail` i `chown 775` and did not realize.
> Also make sure the uid/gid is the same on all nodes.
good hint! i am testing on different machines/os. thanks a lot.
andreas
i`m still looki
05.06.2013 21:30, paul wrote:
> Hi. I have followed the Clusters from scratch PDF and have a working two
> node active passive cluster with ClusterIP, WebDataClone,WebFS and
> WebSite working. I am using BIND DNS to direct my websites to the
> cluster address. When I perform a failover which works
Hi. I have followed the Clusters from scratch PDF and have a working two
node active passive cluster with ClusterIP, WebDataClone,WebFS and
WebSite working. I am using BIND DNS to direct my websites to the
cluster address. When I perform a failover which works ok I have to
restart BIND on the now a
15 matches
Mail list logo