2013.07.18. 18:27 keltezéssel, Nikolay Martynov írta:
> Looks like trunk@37090 has changed the logic that determines if router's
> button was pressed. This resulted in TEW632BRP always booting into failsafe
> mode because it detected pressed button (which was not pressed).
>
> Measure with voltm
Hi.
I've submitted this patch some time ago but haven't seen any response or
feedback to it. I believe that this patch fixes very specific, serious and
easily reproducible issue on a specific hardware.
I would appreciate if somebody could let me know if I've sent this patch
in wrong format or
Looks like trunk@37090 has changed the logic that determines if router's button
was pressed. This resulted in TEW632BRP always booting into failsafe mode
because it detected pressed button (which was not pressed).
Measure with voltmeter has shown that buttons on this router are actually
active-