tephen Duffull; Andre Jackson; nmusers
Subject: Re: [NMusers] Splitting the residual error
Hi Steve and Andre,
No, nothing fancy, I did not even estimate the time of the switch. Something
like this:
ITAD=1
IF(TAD.LE.4) ITAD=THETA(10)
Y=F + (F*ITAD*ERR(1)+ERR(2))
ITAD can also include differen
Gibiansky
*Sent:* Saturday, 14 May 2016 2:07 a.m.
*To:* Jonathan Moss ; nmusers@globomaxnm.com
*Subject:* Re: [NMusers] Splitting the residual error
Dear Jon,
We routinely use separate residual errors during absorption and later
(say, a larger error in the first X hours), although I do not remember
s/>
*From:*owner-nmus...@globomaxnm.com
[mailto:owner-nmus...@globomaxnm.com] *On Behalf Of *Jonathan Moss
*Sent:* Friday, May 13, 2016 11:37 AM
*To:* nmusers@globomaxnm.com
*Subject:* [NMusers] Splitting the residual error
Dear all,
I would like to share with you and get people’s opinions on a recent
iss
r-nmus...@globomaxnm.com [mailto:owner-nmus...@globomaxnm.com] On
Behalf Of Jonathan Moss
Sent: Friday, May 13, 2016 11:37 AM
To: nmusers@globomaxnm.com
Subject: [NMusers] Splitting the residual error
Dear all,
I would like to share with you and get people's opinions on a recent issue I
Dear all,
I would like to share with you and get people's opinions on a recent issue I
had.
I have a data set of 46 patients, orally dosed, with very dense sampling
during absorption (0.25h, 0.5h, 0.75h, 1h, 1.5h, 2h, 3h, 4h, 6h, 8h, 12h,
24h, 36h), Cmax at around 4 hours.
During modelling, I