Re: [PATCH v6 3/3] can: sja1000: of: add compatibility with Technologic Systems version

2016-01-21 Thread Marc Kleine-Budde
On 01/21/2016 04:28 PM, Damien Riegel wrote: > I tested the new technologic version and it works as expected. Thanks. > Would be nice if someone could test the nxp version to ensure no > regressions has been introduced (I don't have such hardware here). I don't have the hardware, either. Marc -

Re: [PATCH v6 3/3] can: sja1000: of: add compatibility with Technologic Systems version

2016-01-21 Thread Damien Riegel
Hi Marc, I tested the new technologic version and it works as expected. Would be nice if someone could test the nxp version to ensure no regressions has been introduced (I don't have such hardware here). On Wed, Jan 20, 2016 at 04:43:31PM +0100, Marc Kleine-Budde wrote: > From: Damien Riegel >

[PATCH v6 3/3] can: sja1000: of: add compatibility with Technologic Systems version

2016-01-20 Thread Marc Kleine-Budde
From: Damien Riegel Technologic Systems provides an IP compatible with the SJA1000, instantiated in an FPGA. Because of some bus widths issue, access to registers is made through a "window" that works like this: base + 0x0: address to read/write base + 0x2: 8-bit register value This com