On 04/04/2017 11:34 AM, Marc Kleine-Budde wrote:
> On 03/24/2017 06:20 PM, Akshay Bhat wrote:
>> Hi Marc,
>>
>> On 03/17/2017 05:10 PM, Akshay Bhat wrote:
>>> This patch adds support for the Holt HI-311x CAN controller. The HI311x
>>> CAN controller is capable of transmitting and receiving standa
On 03/24/2017 06:20 PM, Akshay Bhat wrote:
> Hi Marc,
>
> On 03/17/2017 05:10 PM, Akshay Bhat wrote:
>> This patch adds support for the Holt HI-311x CAN controller. The HI311x
>> CAN controller is capable of transmitting and receiving standard data
>> frames, extended data frames and remote frames
Hi Marc,
On 03/17/2017 05:10 PM, Akshay Bhat wrote:
> This patch adds support for the Holt HI-311x CAN controller. The HI311x
> CAN controller is capable of transmitting and receiving standard data
> frames, extended data frames and remote frames. The HI311x interfaces
> with the host over SPI.
>
Hi Wolfgang,
On 03/20/2017 12:46 PM, Wolfgang Grandegger wrote:
..snip..
>>
>> The top 3 bits of HI3110_READ_ERR (BUSOFF, TXERRP, RXERRP) are valid
>> even if HI3110_INT_BUSERR is not set.
>
> I'm confused! If you disable BUSERR interrupts, you do not get the
> status bits any longer, you said. B
Hello Akshay,
Am 20.03.2017 um 16:14 schrieb Akshay Bhat:
Hi Wolfgang,
On 03/19/2017 12:17 PM, Wolfgang Grandegger wrote:
Hello Akshay,
I still see some improvements...
Am 17.03.2017 um 22:10 schrieb Akshay Bhat:
This patch adds support for the Holt HI-311x CAN controller. The HI311x
CAN co
Hi Wolfgang,
On 03/19/2017 12:17 PM, Wolfgang Grandegger wrote:
> Hello Akshay,
>
> I still see some improvements...
>
> Am 17.03.2017 um 22:10 schrieb Akshay Bhat:
>> This patch adds support for the Holt HI-311x CAN controller. The HI311x
>> CAN controller is capable of transmitting and receivi
Hello Akshay,
I still see some improvements...
Am 17.03.2017 um 22:10 schrieb Akshay Bhat:
This patch adds support for the Holt HI-311x CAN controller. The HI311x
CAN controller is capable of transmitting and receiving standard data
frames, extended data frames and remote frames. The HI311x int
This patch adds support for the Holt HI-311x CAN controller. The HI311x
CAN controller is capable of transmitting and receiving standard data
frames, extended data frames and remote frames. The HI311x interfaces
with the host over SPI.
Datasheet: www.holtic.com/documents/371-hi-3110_v-rev-jpdf.do