On Fri, Mar 19, 2021 at 04:56PM +0800, Russell King - ARM Linux admin wrote:
> On Fri, Mar 19, 2021 at 08:40:45AM +0100, Heiner Kallweit wrote:
>> Is there a specific reason why c22 is probed first? Reversing the order
>> would solve the issue we speak about here.
>> c45-probing of c22-only PHY's s
On Fri, Mar 19, 2021 at 08:40:45AM +0100, Heiner Kallweit wrote:
> Is there a specific reason why c22 is probed first? Reversing the order
> would solve the issue we speak about here.
> c45-probing of c22-only PHY's shouldn't return false positives
> (at least at a first glance).
That would likely
On 18.03.2021 10:09, Wong Vee Khee wrote:
> When using Clause-22 to probe for PHY devices such as the Marvell
> 88E2110, PHY ID with value 0 is read from the MII PHYID registers
> which caused the PHY framework failed to attach the Marvell PHY
> driver.
>
> Fixed this by adding a check of PHY ID e
On 3/18/2021 11:14 AM, Greg KH wrote:
> On Thu, Mar 18, 2021 at 09:02:22AM -0700, Florian Fainelli wrote:
>>
>>
>> On 3/18/2021 6:25 AM, Heiner Kallweit wrote:
>>> On 18.03.2021 10:09, Wong Vee Khee wrote:
When using Clause-22 to probe for PHY devices such as the Marvell
88E2110, PHY I
On Thu, Mar 18, 2021 at 09:02:22AM -0700, Florian Fainelli wrote:
>
>
> On 3/18/2021 6:25 AM, Heiner Kallweit wrote:
> > On 18.03.2021 10:09, Wong Vee Khee wrote:
> >> When using Clause-22 to probe for PHY devices such as the Marvell
> >> 88E2110, PHY ID with value 0 is read from the MII PHYID re
On 18.03.2021 17:02, Florian Fainelli wrote:
>
>
> On 3/18/2021 6:25 AM, Heiner Kallweit wrote:
>> On 18.03.2021 10:09, Wong Vee Khee wrote:
>>> When using Clause-22 to probe for PHY devices such as the Marvell
>>> 88E2110, PHY ID with value 0 is read from the MII PHYID registers
>>> which caused
On Thu, Mar 18, 2021 at 09:02:22AM -0700, Florian Fainelli wrote:
> On 3/18/2021 6:25 AM, Heiner Kallweit wrote:
> > On 18.03.2021 10:09, Wong Vee Khee wrote:
> >> When using Clause-22 to probe for PHY devices such as the Marvell
> >> 88E2110, PHY ID with value 0 is read from the MII PHYID register
On 3/18/2021 6:25 AM, Heiner Kallweit wrote:
> On 18.03.2021 10:09, Wong Vee Khee wrote:
>> When using Clause-22 to probe for PHY devices such as the Marvell
>> 88E2110, PHY ID with value 0 is read from the MII PHYID registers
>> which caused the PHY framework failed to attach the Marvell PHY
>>
On 18.03.2021 10:09, Wong Vee Khee wrote:
> When using Clause-22 to probe for PHY devices such as the Marvell
> 88E2110, PHY ID with value 0 is read from the MII PHYID registers
> which caused the PHY framework failed to attach the Marvell PHY
> driver.
>
> Fixed this by adding a check of PHY ID e
When using Clause-22 to probe for PHY devices such as the Marvell
88E2110, PHY ID with value 0 is read from the MII PHYID registers
which caused the PHY framework failed to attach the Marvell PHY
driver.
Fixed this by adding a check of PHY ID equals to all zeroes.
Fixes: ee951005e95e ("net: phy: