From: Jon Maloy
Date: Fri, 25 Nov 2016 10:35:02 -0500
> In commit e4bf4f76962b ("tipc: simplify packet sequence number
> handling") we changed the internal representation of the packet
> sequence number counters from u32 to u16, reflecting what is really
> sent over the wire.
>
> Since then some
In commit e4bf4f76962b ("tipc: simplify packet sequence number
handling") we changed the internal representation of the packet
sequence number counters from u32 to u16, reflecting what is really
sent over the wire.
Since then some link statistics counters have been displaying incorrect
values, par