On 03-10-16 16:35, Andrew Lunn wrote:
+Boolean:
+
+ - enable-edpd : Not related to timing. Specify this property to enable
+ energy-detect power-down mode in the PHY.
The Broadcom PHYs unconditionally enable this feature.
The SMSC driver has an option: smsc,disabl
> +Boolean:
> +
> + - enable-edpd : Not related to timing. Specify this property to enable
> + energy-detect power-down mode in the PHY.
The Broadcom PHYs unconditionally enable this feature.
The SMSC driver has an option: smsc,disable-energy-detect because it
seems
Set bit 0 in register 1C.23 to enable the EDPD feature of the
KSZ9031 PHY. This reduces power consumption when the link is
down. To use this, set "enable-edpd" in the devicetree.
Signed-off-by: Mike Looijmans
---
.../devicetree/bindings/net/micrel-ksz90x1.txt| 6 ++
drivers/net/phy/