2016-07-08 15:22 GMT+03:00 Veli-Matti Lintu :
> 2016-07-08 4:48 GMT+03:00 Jay Vosburgh :
>> diff --git a/drivers/net/bonding/bond_3ad.c b/drivers/net/bonding/bond_3ad.c
>> index edc70ffad660..2da5be91226e 100644
>> --- a/drivers/net/bonding/bond_3ad.c
>> +++ b/dri
2016-07-08 4:48 GMT+03:00 Jay Vosburgh :
> Veli-Matti Lintu wrote:
>
>>2016-07-06 0:20 GMT+03:00 Jay Vosburgh :
>>Thanks for the pointers. Adding some extra debug in __enable_port
>>helped me to get in right direction. And adding quite a bit of extra
>>debug informa
2016-07-06 0:20 GMT+03:00 Jay Vosburgh :
> Veli-Matti Lintu wrote:
>
>>2016-06-30 14:15 GMT+03:00 Veli-Matti Lintu :
>>> 2016-06-29 18:59 GMT+03:00 Jay Vosburgh :
>>>> Veli-Matti Lintu wrote:
>>
>>>> I tried this locally, but don't
2016-07-05 17:01 GMT+03:00 Veli-Matti Lintu :
> 2016-06-30 14:15 GMT+03:00 Veli-Matti Lintu :
>> 2016-06-29 18:59 GMT+03:00 Jay Vosburgh :
>>> Veli-Matti Lintu wrote:
>
>>> I tried this locally, but don't see any failure (at the end, the
>>> &q
2016-06-30 14:15 GMT+03:00 Veli-Matti Lintu :
> 2016-06-29 18:59 GMT+03:00 Jay Vosburgh :
>> Veli-Matti Lintu wrote:
>> I tried this locally, but don't see any failure (at the end, the
>> "Switch A" agg is still active with the single port). I am sta
ehow?
Veli-Matti
>
> Let me know the result.
> Zhu Yanjun
>
> On Tue, Jun 28, 2016 at 7:57 PM, Veli-Matti Lintu
> wrote:
>>
>> 2016-06-24 0:20 GMT+03:00 Jay Vosburgh :
>> >
>> > Since commit 7bb11dc9f59d ("bonding: unify all places wher
2016-06-29 18:59 GMT+03:00 Jay Vosburgh :
> Veli-Matti Lintu wrote:
> [...]
>>Thanks for the patch. I have been now testing it and the reselection
>>seems to be working now in most cases, but I hit one case that seems
>>to consistently fail in my test environment.
>
th" and
> "count" options only consider ports that are link up.
>
> Second, on any carrier state change of any slave, the aggregator
> selection logic is explicitly called to insure the correct aggregator is
> active.
>
> Reported-by: Veli-Matti Lintu
&
2016-06-22 3:49 GMT+03:00 Jay Vosburgh :
>
> Veli-Matti Lintu wrote:
> [...]
>>>>The ports are configured in switch settings (HP Procurve 2530-48G) in
>>>>same trunk group (TrkX) and trunk group type is set as LACP.
>>>>/proc/net/bonding/bond0 a
2016-06-21 18:46 GMT+03:00 Jay Vosburgh :
> Veli-Matti Lintu wrote:
>
>>2016-06-20 17:11 GMT+03:00 zhuyj :
>>> 5. Switch Configuration
>>> ===
>>>
>>> For this section, "switch" refers to whatever system the
>
2016-06-20 17:11 GMT+03:00 zhuyj :
> 5. Switch Configuration
> ===
>
> For this section, "switch" refers to whatever system the
> bonded devices are directly connected to (i.e., where the other end of
> the cable plugs into). This may be an actual dedicated switch devic
Hello,
I have been trying to get the bonding driver working with multiple
aggregators with two switches in mode=802.3ad to handle failing links
properly. The goal is to have always the best possible bonded link in
use if one or physical links fail.
The bonding documentation describes that 802.3ad
12 matches
Mail list logo