At this point I’m considering leasing a routable public IP address or a
block of addresses for the ZyXEL
In this way the ATM/PTM traffic & PPPoE encapsulation is telco/ISP specific &
an OpenBSD device can be assigned an ethernet port & public IP if needed
Regards
Patrick
> On Mar 19, 2017, at 2:
Hi,
Another thing to check is whether the PPPoE tunnel is trying to negotiate
IPv6. I had this happen with my ISP. I was disconnecting every 5-6 minutes.
I ended up changing my hostname.pppoe0 to:
inet 0.0.0.0 255.255.255.255 NONE \
pppoedev re0 authproto chap \
authname 'u...@example.com' up
d
I’ve also been troubleshooting frequent PPPoE issues with an OpenBSD router
at this point my troubleshooting has resulted in the following:
The residential ISP supplied ZyXEL C100Z currently supports forty five days
plus of PPPoE uptime
It appears the C100Z PTM (Packet Transfer Mode) traffic is
On 2017-03-17, Nicholas Bachmann wrote:
> Hi all,
>
> I’m having a problem where PPPoE disconnects every 6-7 minutes. I’m
> originally saw this in 5.9; I then upgraded to 6.0 but still have the
> same issue.
>
> If I run “ifconfig pppoe0 up” right after it disconnects, it comes
> right back up aga
Hi all,
I’m having a problem where PPPoE disconnects every 6-7 minutes. I’m
originally saw this in 5.9; I then upgraded to 6.0 but still have the
same issue.
If I run “ifconfig pppoe0 up” right after it disconnects, it comes
right back up again. I have a ddwrt box that can successfully keep
this
5 matches
Mail list logo