Jeff
Staring a Wiki to capture information on Pha 5.6 would be great.
We plan to move to 5.6 next year and lessons learned by others would of
great benefit. Plus I think others could use this for reference when having
issue. Would not mind helping to get it started.
Elizabeth Kirk
I have an Applications Analyst III position open on my Applications Team
here at Suburban Hospital, located in Bethesda, MD.
This position would serve as the clinical analyst for the Pharmacy
Department, working with their departmental super users, to maintain,
clean-up, and configure the MEDIT
Thanks - I did get a reply that described the use of 1527 xx variables - quite
astounding - so I would think that there is no limit. You are correct on the
limitation mentioned below - and also on the way around this limitation - by
calling additional fragments! Joe's solution is of course a c
You can do it this way. Create a frag report with a macro like this
(I named it LAB.P.SPEC.zcus.codes.frag.path and the macro name is doit)
; Call std results looping pgm with proper arguments.;; Requires /urn and /LAB.C.RFMT.mnemonic.;Q(/urn,/LAB.C.RFMT.mnemonic,/CONF,"",1)^/ARG,
With our previous bar-coded medication administration system, we used a
handheld device exclusively for documentation. The screen size was an issue for
the nurses. They had to use their stylus, or heaven forbid, their pen to scroll
down and over to see all of the information, especially when ack
I am curious, has anyone been able to create edits to the preference
card? I would love to add to the header, but this seams an impossible
taskif you have could you share your methods?
Coral R. Miller
Sr. Analyst, Clinical Informatics
Olympic Medical Center
=*=*=*=*=*=*=*=*=*=*=*=
Good Morning,
I was wondering if anyone had any information about a successful implementation
of any form of Handheld for PCS/ED documentation of assessments using a
Handheld device for Client Server?
I am looking into different hardware options for our Nurses and NA/PCT's who
will be document
Danny -
I would recommend Park Place for IBM or HP choices, and also Castle
Systems for HP preferences.
David Dawdy
Director of Information Systems
Memhosp
IL
"Danny Miles" <[EMAIL PROTECTED]>
Sent by: [EMAIL PROTECTED]
07/12/2007 11:05 AM
To
cc
Subject
[MEDITECH-L] New hardware platfo
I have a problem with the current/standard List Location Activity report that
is on the Ancillary Menu in OE.
We have found this report to be very helpful. It shows all the patients
entering and leaving a specific unit. This can really demonstrate the workload
on a unit. If they have 15 discharg
Good morning to everyone! Since making the initial conversion from 3-COM to
Xyplex 1620
TS approximately (1) year ago we have consistently experienced the problem
of "unreadable
characters" on our Fargo Prodigy barcode printers in the LAB. The problem
seems to be
worse sometimes than others. Th
We are a Magic 5.4 facility. I am testing a footnote posted on Meditech
Knowledge Base Article 10904 which
does not work in Admitting.
Is there anyone who prints to a specific tray on HP 4050 printer and
willing to share the information.
Your help is greatly appreciated.
Steve Warycha
St. John
We have used i-STAT for years and like it very much. We do all of our
blood gases on it and use it in the ER and in Surgical Services for
chemistries and H&H. We use a script interface to get the results into
the Lab system.
Diane
Diane Goldstein, IT Project Leader
Doctors Community Hospita
Hello LSS EAR users, what are you using for your HIPAA audit log of user
access to accounts? I'd like to see if someone has a better idea than
our current practice.
Regards,
Peggy
Peggy Esch, MBA CPHIMS
HCIS Manager
Citizens Memorial Healthcare
1500 N. Oakland
Bolivar, Missouri 65613
There are a number of factors to keep in mind when running wireless
networks and voip phones.
First and foremost, wireless is a shared environment, whereas hard wired
devices are not (or at least you control how many devices are on a
drop). What this means is that the wireless access POD in the c
Hi all,
Does anyone know of something in PCS that shows who acknowledged the
order on the Status Board? We have the Acknowledgment Log report but
the managers are hoping for something "on line" in the status board that
shows who acknowledged the order.
Any suggestions/insight will be greatly app
Positions available both in house at HSM and also with client
sites/companies.
If you have a solid MEDITECH skill set send your resume to
[EMAIL PROTECTED] or feel free to call 781-749-4022.
We currently have a high demand for people skilled in the MEDITECH
clinical applications, C/S experience
I'm trying to find contacts that are using the above modules and the
inventory interface in the Client Server environment that would be
willing to share their experiences, good and bad, in using the
interface. We are finally migrating to the Meditech modules from ESI and
would appreciate any input
Steve:
I have been successful in printing to multiple trays on a printer (e.g., UB04
claims in the upper tray, regular paper in the lower tray), at least on the HP
LaserJet 4150. Meditech states, and also defines in a Knoweldge Base article,
that they can't control tray usage, at least in repo
We are looking for another hospital that downloads patient
UB-04/HCFA1500 claims from Magic to Relay Health's ePremis product.
Specifically, we are trying to determine how other Meditech users are
handling secondary claim formulation. Thanks, Bill
Bill O'Brien
Information Technology Manager
Kel
Hi Dale,
We've been using Xyplex since 1998 and just started having this problem about a
month ago. I
had to slow down the Fargos from 9600 to 2400 baud and of course change the
Xyplex settings to
match. No problems since they do complain the labels come out slower but
now they can at
le
I'm new to writing attributes and I'm hoping someone can help with what seems
like a simple attribute. My goal is to have the insurance authorization number
display on a OE CDS. I've been unsuccessful with a variety of options. The
attribute below will seem to work once, but when I go to a subse
Hi,
We are wondering if anyone in Meditech-land is familiar with the IDM Prelude
Software used for blood bank donors. We collect about 12,000 units per year.
Also does anyone have a Meditech Donor questionnaire they would be willing to
share? We are currently using paper.
Thanks and have a g
Please post to L.
_
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Bell, Cory
Sent: Wednesday, July 11, 2007 1:14 PM
To: meditech-l@mtusers.com
Subject: [MEDITECH-L] Change Control Process/Policy
Hi,
We would be interested to know what other Meditech hospitals are
I was just asked to rebuild a couple of the standard transcription reports
from OE and RAD so that our transcriptionists would only be able to view
their own statistics. While doing this, I have discovered that the reports
are also counting blank lines for the OE reports. I have not checked the
R
Kalispell Regional Medical Center, located in Kalispell, Montana has an
opening for a full time applications specialist. We are primarily a
Meditech Client Server site. Kalispell is 25 miles from the west
entrance of Glacier National Park, 20 miles to Flathead Lake or
Whitefish Mountain Ski Resort
Hi Folks,
Can any of you tell me if your site uses the ADM Bed Swap routine?
Our folks here have been told not to, and just wondering why this might
be... Also curious as to if you use it and if you have any external
vendors...
Any thoughts or feedback would be great to know!
Damia
For those sites that have implemented BMV/eMAR - I have several questions
about post go live monitoring
1. What are you monitoring? (Scanning compliance, variance times,
documentation issues etc..??)
2. What tools are you using (I have not found the standard Meditech
reports to be helpful. Fo
Are there any hospitals in Wisconsin that are Critical Access and doing
Billing Method II for non-employed physicians?
If there is, I would really like to talk with you. We are looking into this
and have many questions.
Thanks.
Marisse
Marisse Miller-Krishka
Information Systems - Financial
28 matches
Mail list logo