Hi Jim: I have to agree with you on that point. Meditech has spread its
programmers too thin and they do not have enough knowledgeable people to do the
work that needs to be done. It also takes a long time to learn what needs to be
done and how to do it, so if you have someone who is good at som
Do your rehab disciplines use the same basic assessment, treatment and
progress screens regardless of the patient's locale (acute vs. acute
rehab vs. skilled). If yes, are FIMS and MDS scales incorporated into
the documentation or is there a separate process, be it manual or
automated, for converti
create a bogus sort with a trailer key and do your totals there.
xx.sort
DAT=FREE
VAL=1
Thank you,
Mitch Lawrence
Lead Applications Analyst - Advanced Report Writer
General Financials Support
CHRISTUS Information Management
': 361.881.3408 7: 361.888.6117
È: 361.549.8456 )AIM: a1d13 )MSN: [EMA
Hi All,
The schedulers want the appointment letter to print twice when the print
from scheduling. They may choose one appointment or 12 appointments so I
can't have it format correctly in the letter dictionary if I try to set up
the letter twice within one letter. Has anyone done this? Can it b
Add a fake computed sort to your NUR fragment
xx.fake.sort
DAT=INT
LEN=1
VAL=1
Make this the primary sort of the fragment, give the sort a TK region
(TK1) and put your totals in that region.
It will work just like a TR because every record will be in the first
(and only) sort group, and it will
Please post to list.
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Hufford,
Lorraine
Sent: 02 July 2007 04:48 PM
To: meditech-l@mtusers.com
Subject: [MEDITECH-L] ISBT
Good morning!
Has anyone had success building product dictionaries f
If the letter will be one page, you can sneak a multiple copies command
into your report. If it is multiple pages, your copies won't collate,
but you can still set it up to print two.
Send this command anywhere on the page.
D(27)_"&l2X"^!
The l is a lower case L.
Joe Cocuzzo
Vice President
N
This hurt to read (paragraphs are your friend), but is a very good
point.
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
[EMAIL PROTECTED]
Sent: Monday, July 02, 2007 8:36 PM
To: Lehl, Jim
Cc: MEDITECH-L@MTUsers.com
Subject: Re: [MEDITECH-L] Buggy Meditec
The Royal Victoria Hospital is currently seeking a SQL and Oracle
Database Adminstrator. The RVH is located in the city of Barrie which
is within 45 minutes Toronto and surrounds the shores and beaches of
Kempenfelt Bay, on beautiful Lake Simcoe. Barrie is home to many
four-season activities and
How are other sites handling charge master/claim dictionary set up for
anesthesia 1500 billing? One charge for BUV and Minutes with correct
units.
Charlie Caruso
CIO
Goodall Hospital
25 June Street
Sanford, ME 04073
Phone: 207-490-7481
email: [EMAIL PROTECTED]
=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*
I would very much like to connect with the analyst from Door County
Memorial in Sturgeon Bay, Wisconsin. I have a general phone number, so I
can always go that route, but I thought I would start here. If anyone
has the e-address for this person, I would appreciate it. Sharon
Sharon LaDuke RN BS
Please post.
Thanks,
Terry Angeloni
Clinical Application Specialist II
Provena Health Information Services
2175 W. Oneida St.
Joliet, IL 60435
Ph: 815-730-2858
Fx: 815-744-7565
[EMAIL PROTECTED]
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On B
I believe the "Face Sheets" can be Archived (OD) when they purge.
Rich McNeil
MIS Project Leader
Southcoast Hospitals Group
New Bedford, MA 02740
E-Mail: [EMAIL PROTECTED]
Phone: 508-910-3822
%%
Mon Jul 2,
Daisy, we re-print them out of PCI.
Renee' Rinehart, HCIS Financial Coordinator
Guadalupe Regional Medical Center
Seguin, Texas 78155
830-401-7214
[EMAIL PROTECTED]
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] Behalf Of Daisy Reyna
Sent: Monday, July 02, 2007 4:1
You are correct Alan that this is a work-around, but your only other option is
to add the NF item to your Formulary which in turns makes for an extremely busy
(read as: dangerous) Drug dictionary. Of course there is the strict NF policy
as noted earlier.
Alan Miller <[EMAIL PROTECTED]> wrote:
In your opinion is it easier for a barcode reader to read thermal labels or
labels printed by ribbon? (Please don't factor in the difficulty of loading
and maintaining the ribbon).
=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=
To subscribe or unsubscribe to the meditech-l, visit
http://mtusers.com/
The Royal Victoria Hospital is currently seeking an Interface / HL7
Programmer. The Royal Victoria Hospital is located in the city of
Barrie which is within 45 minutes Toronto and surrounds the shores and
beaches of Kempenfelt Bay, on beautiful Lake Simcoe. Barrie is home to
many four-season act
Couldn't you just add a trailer to the primary sort and use it instead
of adding a computed sort?
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Joe Cocuzzo
Sent: Monday, July 02, 2007 9:17 PM
To: Randy Suinn; meditech-l@mtusers.com
Subject: Re: [MEDITEC
Hi Janet,
Attached is an NPR report that checks for positive falls risks as documented
(most recent and skip undoes).
Marc
Marc Benoy RN, MS, MBA
Clinical IT Project Manager
301.552.8876 (Phone)
301.552.8181 (Fax)
[EMAIL PROTECTED]
Doctors Community Hospital
8118 Good Luck Road
Lanham, MD 207
Hi,
I just wanted to reply to this message. I worked for Meditch for 5 years as a
support rep. I supported Pharmacy and we did have a Pharmacist on staff. As
far as I know, he is still there.
When problems are called in, we tested the problems in the customer's TEST
directory at Meditech and
Thanks for the explanation.
Donald
-Original Message-
From: Joe Cocuzzo [mailto:[EMAIL PROTECTED]
Sent: Tuesday, July 03, 2007 10:20 AM
To: Stewart, Donald; Randy Suinn; meditech-l@mtusers.com
Subject: RE: [MEDITECH-L] NPR-fragments question - grand total in
fragment
He wanted TR behavi
Kevin,
I added a barcode of the RX number to our med label and label.th
formats. We'll PL and use these to "tag" each individual dose of NF's.
This seems to be the least painful addition to our current NF practices
and gives the nurses something to scan. This will help keep the
Dictionary clean a
Good Morning,
We are now struggling with documentation of Critical Pathways. Has anyone
devised a way to utilize Pathways other then MEDITECH's standard? If so,
would you mind sharing your documentation screens?
Thanks in advance.
Mary Hayward RN, BSN
Applications Supervisor
Bay
He wanted TR behavior (grand totals)
If the primary sort could have more than one value, you won't get grand
totals in the trailer, you'll get subtotals for that sort value.
It is easier to make up a fake sort that absolutely will just have 1
value than to decide that the primary sort (for example
Hi Everyone,
A few weeks ago, someone asked about criteria for Falls Assessments. I mentioned the "Criteria Analysis" section of Picis QM module and got a flood of responses. I thought I'd just do a write up on how it works and how you can set it up and use it.
Example: Say you have an inciden
They can be archived in C/S, as we send them to Data Archiving, and it's
working.
Mary Ricke, RHIT
IT Department
Hays Medical Center
Hays, KS 67601
785-623-2126
[EMAIL PROTECTED]
-Original Message-
>From [EMAIL PROTECTED]
Sent Tue 7/3/2007 3:48 AM
To meditech-l@mtusers.com
Subject Re:
Hello there,
We are a Magic 5.4 facility whose faxes (running off of an Interbit Fax
Server) have been corrupted for days. It looks like some of the lines
are running into the line below.
We have reset everything, checked phone lines, refiled the coversheet,
moved the Fax Server to a new outboun
I don't know if this will help anyone, but attached is a NPR report I
call my "Silly Little Drug Barcode Report". It is formatted for a 3 1/2
inch X 1 inch label and tested on a thermal DataMax I-4208 printer. When
you run it, it asks for a drug name, Lot Number, Expiration Date, and
Number of Copi
I have a different take on this - and none of it is simple. I worked 13 years
at Meditech in clinical development as a programmer. In all of those years I
only met 1 in-house clinician - Dr. Pope - who worked mostly on PCI. I worked
mostly on LAB/MIC/BBK. At one point - as we developed the NP
I am again needing some help with an attribute. Because we are testing
something new with only one unit, I want to pop up a message for them
that they must document but remind other units that it is for the pilot
unit only at this time. What I have is below but it does not pass the
syntax che
We are about to get the following put in our TEST system. Has anyone had
experience with these Maigc ORM DTSs ? If so any issues ?
Meditech ORM - DTS/FIX: 4678, 4916, 4881, 4825, 4989, 4767
We are Magic 5.5 SR2
Thanks - Deb
Deborah Tullman, PT
MIS Clinical Application Coordinat
Hi Folks,
It's been a while since I've needed to do some mathematical rounding with NPR,
but I'm hoping folks can help... Right now I have a matrix that I built in a
NPR Macro that looks like the following visually:
|
|MIN) (MAX)
Hi Jeanne,
Try this one:
[EMAIL PROTECTED]'=".2N" @W.err("No answer.");@W.err("Answer.")}
Marc
Marc Benoy RN, MS, MBA
Clinical IT Project Manager
301.552.8876 (Phone)
301.552.8181 (Fax)
[EMAIL PROTECTED]
Doctors Community Hospital
8118 Good Luck Road
Lanham, MD 20706
Magic 5.61
From: [EMAIL P
Hi,
We now have the following positions available:
* Admissions/Abstracting IS Analyst in Massachusetts. Full time with benefits.
* Consulting contract for someone who knows Meditech's ED - travel required
* Meditech PCS Consultant - travel required
* Consultant on either a 1099 basis or W2.
If
My recommendation: Take the numbers that you get in 2 decimals and use
a computed variable to recompute them. You'll need to add .05 to adust
for rounding up and then show only the 1 decimal number. Let's say you
have @variable that produces 0.49; you'll want to do this to it:
xx.var1
DAT=DEC1
Moody, Barbra wrote:
> Hello Everyone,
>
> We are having problems with our wireless carts and our VoIP and we aren't
> sure exactly what's happening. We know that when our VoIP communication
> devices hit the wireless network it knocks everything down to B from G and
> slows everyone down. We
The more modules involved in an issue slows its resolution
exponentially. You can quote me on that. Our pharmacy department has a
carousel and drug packaging dispensing system that has a few issues of
it's own without MediTech's help, but MediTech seems to have the need to
help it have
From: Nan Till
Subject: L
We are currently using forms printing software with Meditech but fear we
may have outgrown it. I am familiar with FormsFast, Formscape, Bluechip
and Iatric Forms on Line. Can anyone provide their success/failures with
any of these products from Meditech ? Thanks.
Nan
Hello Fellow L'ers.
My hospital is currently looking at different systems for 1500 billing.
We would love to hear from everyone to see what you are using and how it
is working for you. Thank you all for your time. Hope you all have a
safe and happy 4th of July!
Thank you again,
Carla
Carla Ful
We use FormFast and are looking at changing to another vendor the end of
this year.
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of White, Scott A
Sent: Tuesday, July 03, 2007 2:07 PM
To: Till, Nan H; meditech-l@mtusers.com
Subject: Re: [MEDITECH-L]
I was asked to post the following to the L:
Please find out what other hospitals are using First Data Bank. We
currently use Medispan and found out that there is quite a big
difference in price for maintenance. Does anyone know if the maintenance
price is based on the size of the hospital? Has an
How does your hospital train your nurses on computer applications such
as nursing documentation, E-mar and BMV?
1) Are your classes held by an IS/IT staff member or a nursing
staff member?
2) How frequently are scheduled classes are held?
3) What is the duration of your clas
Just wondering how other places are handling this issuewe are C/S
5.5 sr 2 .
We are missing some respiratory med doses because here our respiratory
staff give the respiratory meds, but
frequently do not know who needs the med or when it is to be given.
We do use BMV and eMAR here but becaus
I am looking for other users of Meditech's Magic ORM out there. We went
live Feb 6th this year and I just discovered something very disturbing
today with the module and am curious if everyone else knows and how you
work around thisIn ORM you can select 5 CDS' in your parameters so
you don't hav
Does anyone know if it's possible to have a query or a response appear in
bold on a CDS? We're told by Meditech that it can't be done but want to
check with the real experts.
Harlow Sires RN MSN
Clinical Informatics Specialist
Highline Medical Center
Burien, WA
206.431.5373 Ext. 5067
=*=*=*=*=*=*
45 matches
Mail list logo