Hi Lakshmi,
On 2/20/24 10:24 AM, Lakshmi Deverkonda wrote:
Hi,
Sorry, I could not reply on this thread. We tried to handle these issues
in our application code.
One query, what is the write way to delete the lttng logger to stop
logging the events(from the code).
I think that the design of
On 2024-02-23 09:26, Steven Rostedt wrote:
On Mon, 19 Feb 2024 13:01:16 -0500
Mathieu Desnoyers wrote:
Between "sched_process_exit" and "sched_process_free", the task can still be
observed by a trace analysis looking at sched and signal events: it's a zombie
at
that stage.
Looking at the hi
On Fri, 23 Feb 2024 11:54:30 -0500
Mathieu Desnoyers wrote:
> So this sched_process_exit placement was actually decided
> by Karim Yaghmour back in the LTT days (2001). I don't think
> he will mind us moving it around some 23 years later. ;)
And I wonder how many people are involved in this that
On 2/23/24 11:54, Mathieu Desnoyers wrote:
...
So this sched_process_exit placement was actually decided
by Karim Yaghmour back in the LTT days (2001). I don't think
he will mind us moving it around some 23 years later. ;)
Gee ... the shadows are longer than I thought :)
It's all yours. You