On Wed, May 21, 2025 at 10:00:35AM +0100, Jonathan Cameron wrote:
> On Tue, 20 May 2025 16:50:19 -0500
> Bjorn Helgaas wrote:
>
> > From: Bjorn Helgaas
> >
> > DPC Error Source ID is only valid when the DPC Trigger Reason indicates
> > that DPC was triggered due to reception of an ERR_NONFATAL
On Tue, 20 May 2025, Bjorn Helgaas wrote:
> From: Bjorn Helgaas
>
> DPC Error Source ID is only valid when the DPC Trigger Reason indicates
> that DPC was triggered due to reception of an ERR_NONFATAL or ERR_FATAL
> Message (PCIe r6.0, sec 7.9.14.5).
>
> When DPC was triggered by ERR_NONFATAL (
On Tue, 20 May 2025 16:50:19 -0500
Bjorn Helgaas wrote:
> From: Bjorn Helgaas
>
> DPC Error Source ID is only valid when the DPC Trigger Reason indicates
> that DPC was triggered due to reception of an ERR_NONFATAL or ERR_FATAL
> Message (PCIe r6.0, sec 7.9.14.5).
>
> When DPC was triggered by
From: Bjorn Helgaas
DPC Error Source ID is only valid when the DPC Trigger Reason indicates
that DPC was triggered due to reception of an ERR_NONFATAL or ERR_FATAL
Message (PCIe r6.0, sec 7.9.14.5).
When DPC was triggered by ERR_NONFATAL (PCI_EXP_DPC_STATUS_TRIGGER_RSN_NFE)
or ERR_FATAL (PCI_EXP