On Fri, Sep 07, 2007 at 09:11:52AM -0500, Milton Miller wrote:
> I'm sorry, I didn't mean to imply it should be asked / selectable, just
> that the help should be provided. I won't object to leaving it except
> that it asks the average user unnecessary questions. In other words, drop
> the
On Sep 7, 2007, at 4:21 AM, Olof Johansson wrote:
> Some versions of PWRficient 1682M have an interrupt controller in which
> the first register in each pair for interrupt sources doesn't always
> read with the right polarity/sense values.
>
> To work around this, keep a software copy of the regi
Some versions of PWRficient 1682M have an interrupt controller in which
the first register in each pair for interrupt sources doesn't always
read with the right polarity/sense values.
To work around this, keep a software copy of the register instead. Since
it's not modified from the mpic itself, i